Cable Condition Diagnosis of Induced voltage and Sheath Current Monitoring

An integrated system for monitoring the condition of high voltage (HV) power cables and localizing faults is proposed. The methodology focuses on identifying faults in the cable sheath by analyzing sheath system currents in underground cable systems. The approach begins with the development of a numerical model to simulate sheath currents. Following this, the paper presents an analysis of various common and consequential faults based on current measurements at the link cable. Simulations of both normal and fault conditions are provided to assess the feasibility of fault detection. To model a faulted underground cable system, an equivalent circuit is analyzed using a lumped parameter approach. This model allows for the examination of radial configurations of metallic cable sheath grounding and their effect on the induced voltages within the sheath. By modeling and analyzing the monitored sheath currents and induced outer sheath voltage, the fault finding can be determined. Finally, case studies are presented, evaluating the system's performance with varying fault distances and resistances. These evaluations highlight the system's effectiveness in fault localization and condition monitoring

Publication Details

Journal
Journal of Carcinogenesis
Published
2025-01-01
DOI
https://doi.org/10.64149/j.carcinog.24.5s.826-836
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cable Condition Diagnosis of Induced voltage and Sheath Current Monitoring

Journal of Carcinogenesis
Electrical Fault Detection and Protection
article

Cable Condition Diagnosis of Induced voltage and Sheath Current Monitoring

article en

Abstract

An integrated system for monitoring the condition of high voltage (HV) power cables and localizing faults is proposed. The methodology focuses on identifying faults in the cable sheath by analyzing sheath system currents in underground cable systems. The approach begins with the development of a numerical model to simulate sheath currents. Following this, the paper presents an analysis of various common and consequential faults based on current measurements at the link cable. Simulations of both normal and fault conditions are provided to assess the feasibility of fault detection. To model a faulted underground cable system, an equivalent circuit is analyzed using a lumped parameter approach. This model allows for the examination of radial configurations of metallic cable sheath grounding and their effect on the induced voltages within the sheath. By modeling and analyzing the monitored sheath currents and induced outer sheath voltage, the fault finding can be determined. Finally, case studies are presented, evaluating the system's performance with varying fault distances and resistances. These evaluations highlight the system's effectiveness in fault localization and condition monitoring

Journal of Carcinogenesis
Openalex Percentile: Top 75%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.