Magnetosome-Based Immunosensors for Foodborne Pathogen Detection

Foodborne illnesses remain a global challenge, requiring rapid and sensitive detection platforms. We developed a magnetosome-based electrochemical immunosensor for lipopolysaccharide (LPS) antigens from Escherichia coli and Salmonella typhimurium. Magnetosomes isolated from Magnetospirillum sp. RJS1 were characterized by HR-TEM and functionalized with antibodies (2 CFU mL−1), with FTIR confirming successful conjugation. The antibody–magnetosome complexes were immobilized on a chitosan/glutaraldehyde-modified glassy carbon electrode. AFM revealed globular (200–700 nm) and island-like (1–3 µm) features after antigen binding. Electrochemical impedance spectroscopy showed stepwise increases in charge-transfer resistance upon electrode modification and antigen interaction. The sensor exhibited high sensitivity toward E. coli (3–7 CFU mL−1) and Salmonella (3–8 CFU mL−1), achieving an immune sensitivity of 36.24 Ω/CFU mL−1 and a detection limit of 1 CFU mL−1. These results demonstrate the potential of magnetosome-based immunosensors as portable, efficient platforms for the rapid detection of foodborne pathogens in real samples.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-09-22
DOI
https://doi.org/10.3390/chemosensors13090355
Citations
1
Primary Topic
Geomagnetism and Paleomagnetism Studies
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetosome-Based Immunosensors for Foodborne Pathogen Detection

Shiva Kumar Arumugasamy, R. Manikandan, Seung‐Cheol Chang, Narayanaswamy Srinivasan et al.
1 citations
Chemosensors
Geomagnetism and Paleomagnetism Studies
0.81
article

Magnetosome-Based Immunosensors for Foodborne Pathogen Detection

Shiva Kumar Arumugasamy, R. Manikandan, Seung‐Cheol Chang, Narayanaswamy Srinivasan, Sejoon Lee, E. Pavithra Krishnan, Saravanan Sekar, S. Sutha, Sankar Sekar, Sekar Vaithilingam
article en
1 citations

Abstract

Foodborne illnesses remain a global challenge, requiring rapid and sensitive detection platforms. We developed a magnetosome-based electrochemical immunosensor for lipopolysaccharide (LPS) antigens from Escherichia coli and Salmonella typhimurium. Magnetosomes isolated from Magnetospirillum sp. RJS1 were characterized by HR-TEM and functionalized with antibodies (2 CFU mL−1), with FTIR confirming successful conjugation. The antibody–magnetosome complexes were immobilized on a chitosan/glutaraldehyde-modified glassy carbon electrode. AFM revealed globular (200–700 nm) and island-like (1–3 µm) features after antigen binding. Electrochemical impedance spectroscopy showed stepwise increases in charge-transfer resistance upon electrode modification and antigen interaction. The sensor exhibited high sensitivity toward E. coli (3–7 CFU mL−1) and Salmonella (3–8 CFU mL−1), achieving an immune sensitivity of 36.24 Ω/CFU mL−1 and a detection limit of 1 CFU mL−1. These results demonstrate the potential of magnetosome-based immunosensors as portable, efficient platforms for the rapid detection of foodborne pathogens in real samples.

ChemosensorsVol. 13(9)
Dongguk University (KR), Swami Vivekanand College of Pharmacy (IN), Dhanalakshmi Srinivasan Group of Institutions (IN), Pusan National University (KR)
National Research Foundation, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 23%
Geomagnetism and Paleomagnetism Studies
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.