Voltage Surge Estimation in Inverter-Cable High-Impedance Load System

This paper presents a theoretical analysis of inverter–cable–high-impedance load systems using transmission line theory. High-frequency inverters with short voltage rise times can induce severe voltage surges at the load terminal due to impedance mismatch and wave reflections. An analytical expression is derived to estimate the peak terminal voltage as a function of the inverter rise time and cable propagation delay. Simulation results obtained using MATLAB confirm that the peak voltage can surge up to twice the DC link value (300 V for a 150 V DC source) when the inverter rise time is less than three times the cable propagation delay. To mitigate this overvoltage, a dV/dt filter is designed for worst-case rise-time conditions (step input), enhancing surge suppression without requiring redesign across varying switching speeds. The proposed method offers a practical, cost-effective solution for long-cable applications in high-frequency inverter systems.

Authors

Institutions

Publication Details

Journal
Journal of Power, Energy, and Control
Published
2025-09-21
DOI
https://doi.org/10.62777/pec.v2i2.62
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage Surge Estimation in Inverter-Cable High-Impedance Load System

B. Wilson, Ebenezer Armah, Nutifafa Tsikata
Journal of Power, Energy, and Control
HVDC Systems and Fault Protection
article

Voltage Surge Estimation in Inverter-Cable High-Impedance Load System

B. Wilson, Ebenezer Armah, Nutifafa Tsikata
article en

Abstract

This paper presents a theoretical analysis of inverter–cable–high-impedance load systems using transmission line theory. High-frequency inverters with short voltage rise times can induce severe voltage surges at the load terminal due to impedance mismatch and wave reflections. An analytical expression is derived to estimate the peak terminal voltage as a function of the inverter rise time and cable propagation delay. Simulation results obtained using MATLAB confirm that the peak voltage can surge up to twice the DC link value (300 V for a 150 V DC source) when the inverter rise time is less than three times the cable propagation delay. To mitigate this overvoltage, a dV/dt filter is designed for worst-case rise-time conditions (step input), enhancing surge suppression without requiring redesign across varying switching speeds. The proposed method offers a practical, cost-effective solution for long-cable applications in high-frequency inverter systems.

Journal of Power, Energy, and ControlVol. 2(2)
Norfolk State University (US), University of Mines and Technology (GH), University of Energy and Natural Resources (GH)
Openalex Percentile: Top 75%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Voltage Surge Estimation in Inverter-Cable High-Impedance Load System — B. Wilson, Ebenezer Armah, et al. · Journal of Power, Energy, and Control (2025) | TGRS Research Map | TGRS