Flexible Interdigitated Electrode-Enabled Electrochemical Impedance Spectroscopy for Detecting Diesel Contamination in Lubricating Oil

The health status detection of lubricating oil is crucial for the early diagnosis and screening of mechanical damage. This study introduces a flexible interdigitated electrode (IDE)-based electrochemical impedance spectroscopy (EIS) detection method. By analyzing the impact of electrode constants and geometric parameters on detection sensitivity, multiple IDE configurations were designed and fabricated via physical vapor deposition on polyethylene naphthalate (PEN) films for EIS-based assessments. Experimental results demonstrated a significant decrease in impedance magnitude within the $10-10^{3} \mathrm{~Hz}$ frequency range as diesel contamination levels increased, confirming the effectiveness of the flexible interdigitated electrode in detecting diesel-polluted lubricating oils through EIS, and an optimal IDE configuration with the highest sensitivity to contaminant concentration variations was identified. The flexible substrate ensures robust adaptability to dynamic environments and stable physicochemical properties, offering promising potential for in-situ industrial monitoring applications.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/eee64897.2025.11162897
Primary Topic
Lubricants and Their Additives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Interdigitated Electrode-Enabled Electrochemical Impedance Spectroscopy for Detecting Diesel Contamination in Lubricating Oil

Hongpeng Zhang, Wenbo Han, Yi Yang, Lei Zhu et al.
Lubricants and Their Additives
article

Flexible Interdigitated Electrode-Enabled Electrochemical Impedance Spectroscopy for Detecting Diesel Contamination in Lubricating Oil

Hongpeng Zhang, Wenbo Han, Yi Yang, Lei Zhu, Chao Liu, Zhiwei Xu
article en

Abstract

The health status detection of lubricating oil is crucial for the early diagnosis and screening of mechanical damage. This study introduces a flexible interdigitated electrode (IDE)-based electrochemical impedance spectroscopy (EIS) detection method. By analyzing the impact of electrode constants and geometric parameters on detection sensitivity, multiple IDE configurations were designed and fabricated via physical vapor deposition on polyethylene naphthalate (PEN) films for EIS-based assessments. Experimental results demonstrated a significant decrease in impedance magnitude within the $10-10^{3} \mathrm{~Hz}$ frequency range as diesel contamination levels increased, confirming the effectiveness of the flexible interdigitated electrode in detecting diesel-polluted lubricating oils through EIS, and an optimal IDE configuration with the highest sensitivity to contaminant concentration variations was identified. The flexible substrate ensures robust adaptability to dynamic environments and stable physicochemical properties, offering promising potential for in-situ industrial monitoring applications.

Dalian Maritime University (CN)
Openalex Percentile: Top 74%
Lubricants and Their Additives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.