Non-Invasive Intraocular Pressure Monitoring System Based on Amplitude and Phase Detection Technology

This study proposes a non-invasive intraocular pressure monitoring system based on piezoresistive thin-film pressure sensor with amplitude and phase detection technology. The system utilizes the piezoresistive effect of the two-wire piezoresistive sensor to modulate the resistance change caused by intraocular pressure (IOP) into a two-parameter change of RF signal amplitude and phase through electromagnetic induction coupling, and the IOP value is solved by MCU based on the leastsquares fitting after the receiving end has been processed by frequency mixing, filtering, and wave detection. The experiments show that the system fits the real pressure and the converted pressure within the range of $0-30 \mathrm{mmHg}$ with a goodness-of-fit of 0.896, a maximum absolute error of 1.94 mmHg, and an RMSE of 0.49 mmHg, which verifies the feasibility of this non-invasive IOP monitoring scheme.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/isaeece66033.2025.11159916
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Intraocular Pressure Monitoring System Based on Amplitude and Phase Detection Technology

Tongyu Guo, Xin Ma, Xin Zhang
Ocular and Laser Science Research
article

Non-Invasive Intraocular Pressure Monitoring System Based on Amplitude and Phase Detection Technology

Tongyu Guo, Xin Ma, Xin Zhang
article en

Abstract

This study proposes a non-invasive intraocular pressure monitoring system based on piezoresistive thin-film pressure sensor with amplitude and phase detection technology. The system utilizes the piezoresistive effect of the two-wire piezoresistive sensor to modulate the resistance change caused by intraocular pressure (IOP) into a two-parameter change of RF signal amplitude and phase through electromagnetic induction coupling, and the IOP value is solved by MCU based on the leastsquares fitting after the receiving end has been processed by frequency mixing, filtering, and wave detection. The experiments show that the system fits the real pressure and the converted pressure within the range of $0-30 \mathrm{mmHg}$ with a goodness-of-fit of 0.896, a maximum absolute error of 1.94 mmHg, and an RMSE of 0.49 mmHg, which verifies the feasibility of this non-invasive IOP monitoring scheme.

Tiangong University (CN)
Openalex Percentile: Top 62%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.