Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID

In the realm of radiation therapy, the precise positioning of patients constitutes a critical procedure, as it serves to ensure the accurate delivery of radiation doses and minimize the potential damage inflicted upon normal tissues. Accurate positioning not only enhances treatment efficacy but also significantly reduces the likelihood of adverse effects and complications. The Electronic Portal Imaging Device (EPID) is directly integrated into the gantry of a linear accelerator. By using the same source with the treatment, EPID eliminates the mechanical deviation issues inherent in traditional Cone Beam Computed Tomography (CBCT) systems and enables true real-time dose verification. However, applying images acquired by EPID to Mega Voltage Computed Tomography (MVCT) reconstruction and positioning verification still faces significant challenges. EPID captures irregular portal images during treatment, resulting in incomplete projection data, uneven projection angles, and even projection angles missing—all of which pose difficulties for MVCT reconstruction. Additionally, compared with CBCT systems, MVCT shows significantly lower soft-tissue contrast and signal-to-noise ratio. This paper proposes a new method for reconstructing MVCT from irregular portal images acquired by EPID. First, the two-dimensional irregular portal images synchronously collected by EPID during treatment are used as the original data source. After preprocessing, the ART reconstruction algorithm is applied to the pre-processed data, with TV regularization added during the reconstruction process for optimization. Results from the simulations confirm that the proposed algorithm is feasible, satisfactory reconstruction results can be obtained when $\lambda=0.3$ and paceTV=2.0. This method requires no additional operations and does not increase the patient’s radiation dose. The reconstructed MVCT provides technical prerequisites for subsequent positioning verification.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/eee64897.2025.11162770
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID

Zerui Chen, Wei Zhan, Qian Cao, Junhai Wen
Advanced MRI Techniques and Applications
article

Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID

Zerui Chen, Wei Zhan, Qian Cao, Junhai Wen
article en

Abstract

In the realm of radiation therapy, the precise positioning of patients constitutes a critical procedure, as it serves to ensure the accurate delivery of radiation doses and minimize the potential damage inflicted upon normal tissues. Accurate positioning not only enhances treatment efficacy but also significantly reduces the likelihood of adverse effects and complications. The Electronic Portal Imaging Device (EPID) is directly integrated into the gantry of a linear accelerator. By using the same source with the treatment, EPID eliminates the mechanical deviation issues inherent in traditional Cone Beam Computed Tomography (CBCT) systems and enables true real-time dose verification. However, applying images acquired by EPID to Mega Voltage Computed Tomography (MVCT) reconstruction and positioning verification still faces significant challenges. EPID captures irregular portal images during treatment, resulting in incomplete projection data, uneven projection angles, and even projection angles missing—all of which pose difficulties for MVCT reconstruction. Additionally, compared with CBCT systems, MVCT shows significantly lower soft-tissue contrast and signal-to-noise ratio. This paper proposes a new method for reconstructing MVCT from irregular portal images acquired by EPID. First, the two-dimensional irregular portal images synchronously collected by EPID during treatment are used as the original data source. After preprocessing, the ART reconstruction algorithm is applied to the pre-processed data, with TV regularization added during the reconstruction process for optimization. Results from the simulations confirm that the proposed algorithm is feasible, satisfactory reconstruction results can be obtained when $\lambda=0.3$ and paceTV=2.0. This method requires no additional operations and does not increase the patient’s radiation dose. The reconstructed MVCT provides technical prerequisites for subsequent positioning verification.

Beijing Institute of Technology (CN)
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID — Zerui Chen, Wei Zhan, et al. · (2025) | TGRS Research Map | TGRS