Study of Noninvasive Glucose Monitoring Based on FBG for Ballistocardiogram

In this paper, we propose and validate a noninvasive glucose monitoring method based on fiber optic sensing for Heart Rate Variability Ballistocardiography (HRVBCG). The aim was to monitor changes in blood glucose levels by analyzing the HRV parameters derived from the BCG signal. To avoid noise interference with BCG signal extraction, we introduced a variational mode decomposition parameter selection algorithm(S-VMD), which incorporates improvements in center frequency and peak index. Compared with Electrocardiogram (ECG) signals, the maximum relative error in BCG signal feature point localization was 2.63%, and the maximum relative error between HRVECG and HRVBCG parameters was 7.5659%. These results indicate a high degree of consistency in the localization of characteristic points between BCG and ECG signals. This demonstrates that the proposed VMD parameter selection algorithm can effectively extract the BCG signal and retain the signal characteristic point data. To carry out the next step of correlation analysis of blood glucose value and HRV change amount. Experimental results revealed that when volunteers consumed food, their blood glucose levels increased, accompanied by an acceleration in heart rate and a decrease in HRV parameters such as Standard Deviation of NN intervals (SDNN) and Root Mean Square of Successive Differences (RMSSD) began to decrease. The overall correlations between the fitted regression models for the HRV parameters and the amount of change in blood glucose values were all greater than 0.85, and the mean square errors were all less than 0.12. These findings suggest that the inversion of blood glucose parameters through BCG signal monitoring is feasible in the field of noninvasive blood glucose monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3612650
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Noninvasive Glucose Monitoring Based on FBG for Ballistocardiogram

Shao Taoping, Zhichao Liu, Li Xin, Zhang Xi et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
0.67
article

Study of Noninvasive Glucose Monitoring Based on FBG for Ballistocardiogram

Shao Taoping, Zhichao Liu, Li Xin, Zhang Xi, Liu Ziqi
article en
1 citations

Abstract

In this paper, we propose and validate a noninvasive glucose monitoring method based on fiber optic sensing for Heart Rate Variability Ballistocardiography (HRVBCG). The aim was to monitor changes in blood glucose levels by analyzing the HRV parameters derived from the BCG signal. To avoid noise interference with BCG signal extraction, we introduced a variational mode decomposition parameter selection algorithm(S-VMD), which incorporates improvements in center frequency and peak index. Compared with Electrocardiogram (ECG) signals, the maximum relative error in BCG signal feature point localization was 2.63%, and the maximum relative error between HRVECG and HRVBCG parameters was 7.5659%. These results indicate a high degree of consistency in the localization of characteristic points between BCG and ECG signals. This demonstrates that the proposed VMD parameter selection algorithm can effectively extract the BCG signal and retain the signal characteristic point data. To carry out the next step of correlation analysis of blood glucose value and HRV change amount. Experimental results revealed that when volunteers consumed food, their blood glucose levels increased, accompanied by an acceleration in heart rate and a decrease in HRV parameters such as Standard Deviation of NN intervals (SDNN) and Root Mean Square of Successive Differences (RMSSD) began to decrease. The overall correlations between the fitted regression models for the HRV parameters and the amount of change in blood glucose values were all greater than 0.85, and the mean square errors were all less than 0.12. These findings suggest that the inversion of blood glucose parameters through BCG signal monitoring is feasible in the field of noninvasive blood glucose monitoring.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Changchun University of Science and Technology (CN)
Openalex Percentile: Top 27%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of Noninvasive Glucose Monitoring Based on FBG for Ballistocardiogram — Shao Taoping, Zhichao Liu, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS