Magnetically Shielded Room Internal Depth Compensation and Wearable MEG Motion Measurement With Large Spatial Range

The static magnetic field within magnetically shielded room (MSR) is a main factor restricting magnetoencephalography (MEG) if measurements for a moving subject with optically pumped magnetometers (OPMs) are carried out. Existing compensation methods can control it at the nanotesla or sub-nanotesla level, which can meet the measurement during subjects' stationary or small-scale movements. However, this still brings significant motion artifacts. This article studies the spatial distribution characteristics of static residual magnetic fields inside the MSR, and proposes a hybrid coil compensation system. A magnetic field component model is established for all types of coils in the hybrid coil compensation system at various points in space. Then, the distribution pattern of the minimum sensor array and the number of sensors for real-time observation of the magnetic field in space were discussed. Combined with a genetic algorithm (GA), the coil current is optimized to achieve large-scale measurement of motion MEG. The static magnetic field in the central volume of 60×60×15 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> is monitored, and the three static magnetic field components within areas of 10×20 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, 30×40 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and 50×60 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> were accurately controlled to less than 55 pT, 95 pT and 170 pT respectively. Finally, the reliability of the compensation system and algorithm control is verified through auditory stimulation experiments, laying a foundation for the study of motion MEG.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3612637
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetically Shielded Room Internal Depth Compensation and Wearable MEG Motion Measurement With Large Spatial Range

Donghua Pan, Yitao Chen, Chongyu Jin, Liyi Li et al.
IEEE Transactions on Instrumentation and Measurement
Inertial Sensor and Navigation
article

Magnetically Shielded Room Internal Depth Compensation and Wearable MEG Motion Measurement With Large Spatial Range

Donghua Pan, Yitao Chen, Chongyu Jin, Liyi Li, Xinping Dai
article en

Abstract

The static magnetic field within magnetically shielded room (MSR) is a main factor restricting magnetoencephalography (MEG) if measurements for a moving subject with optically pumped magnetometers (OPMs) are carried out. Existing compensation methods can control it at the nanotesla or sub-nanotesla level, which can meet the measurement during subjects' stationary or small-scale movements. However, this still brings significant motion artifacts. This article studies the spatial distribution characteristics of static residual magnetic fields inside the MSR, and proposes a hybrid coil compensation system. A magnetic field component model is established for all types of coils in the hybrid coil compensation system at various points in space. Then, the distribution pattern of the minimum sensor array and the number of sensors for real-time observation of the magnetic field in space were discussed. Combined with a genetic algorithm (GA), the coil current is optimized to achieve large-scale measurement of motion MEG. The static magnetic field in the central volume of 60×60×15 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> is monitored, and the three static magnetic field components within areas of 10×20 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>, 30×40 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and 50×60 cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> were accurately controlled to less than 55 pT, 95 pT and 170 pT respectively. Finally, the reliability of the compensation system and algorithm control is verified through auditory stimulation experiments, laying a foundation for the study of motion MEG.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Harbin Institute of Technology (CN)
Openalex Percentile: Top 66%
Inertial Sensor and Navigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.