VOC injection into a house reveals large surface reservoir sizes in an indoor environment

The total partitioning capacity of indoor surface reservoirs determines the mechanism by which humans receive nondietary exposure to organic contaminants, via inhalation, dermal uptake, and dust ingestion. And yet, this capacity is largely unknown. Surface organic films are ubiquitously present but have very low partitioning volume being only 10's of nanometer thick, whereas other surface reservoirs such as building materials and furnishings can be permeable or porous with large surface areas at the molecular level. Here, we assess the total partitioning capacity of volatile organic compounds (VOCs) in an indoor environment from the measured kinetics of VOC surface uptake after injection of compounds with variable volatility into a well-characterized, unoccupied test house. We show that the size of the indoor surface reservoirs is very large with an octanol-equivalent average thickness on the order of micrometers, indicating that permeable/porous materials such as painted surfaces and wood are likely the major surface reservoirs in the house rather than organic surface films. Large surface reservoirs result in compounds with octanol-air partition coefficients (<i>K</i><sub>OA</sub>) larger than 10<sup>5</sup> being predominantly partitioned to indoor surface reservoirs, making them hard to be removed via ventilation. This result significantly impacts our understanding of VOC fate and human exposure in indoor environments. With such a large partitioning capacity, organic contaminants will have much longer indoor residence times than previously predicted.

Authors

Institutions

Publication Details

Journal
Proceedings of the National Academy of Sciences
Published
2025-09-22
DOI
https://doi.org/10.1073/pnas.2503399122
Citations
4
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
4.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VOC injection into a house reveals large surface reservoir sizes in an indoor environment

Jonathan P. D. Abbatt, Stephen M. Zimmerman, Jenna C. Ditto, Marina E. Vance et al.
4 citations
Proceedings of the National Academy of Sciences
Indoor Air Quality and Microbial Exposure
4.80
article

VOC injection into a house reveals large surface reservoir sizes in an indoor environment

Jonathan P. D. Abbatt, Stephen M. Zimmerman, Jenna C. Ditto, Marina E. Vance, Dustin Poppendieck, Han N. Huynh, Delphine K. Farmer, Manabu Shiraiwa, Michael F. Link, Pascale S. J. Lakey, Jie Yu, Xing Wang
article en
4 citations

Abstract

The total partitioning capacity of indoor surface reservoirs determines the mechanism by which humans receive nondietary exposure to organic contaminants, via inhalation, dermal uptake, and dust ingestion. And yet, this capacity is largely unknown. Surface organic films are ubiquitously present but have very low partitioning volume being only 10's of nanometer thick, whereas other surface reservoirs such as building materials and furnishings can be permeable or porous with large surface areas at the molecular level. Here, we assess the total partitioning capacity of volatile organic compounds (VOCs) in an indoor environment from the measured kinetics of VOC surface uptake after injection of compounds with variable volatility into a well-characterized, unoccupied test house. We show that the size of the indoor surface reservoirs is very large with an octanol-equivalent average thickness on the order of micrometers, indicating that permeable/porous materials such as painted surfaces and wood are likely the major surface reservoirs in the house rather than organic surface films. Large surface reservoirs result in compounds with octanol-air partition coefficients (<i>K</i><sub>OA</sub>) larger than 10<sup>5</sup> being predominantly partitioned to indoor surface reservoirs, making them hard to be removed via ventilation. This result significantly impacts our understanding of VOC fate and human exposure in indoor environments. With such a large partitioning capacity, organic contaminants will have much longer indoor residence times than previously predicted.

Proceedings of the National Academy of SciencesVol. 122(39)
National Oceanic and Atmospheric Administration (US), National Institute of Standards and Technology (US), Applied Science Private University (JO), Cooperative Institute for Research in Environmental Sciences (US), University of Toronto (CA), University of Colorado Boulder (US), University of California, Irvine (US), Washington University in St. Louis (US), NOAA Oceanic and Atmospheric Research (US), National Institute of Standards (EG), Colorado State University (US), University of California, Berkeley (US)
Alfred P. Sloan Foundation, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 5%
Indoor Air Quality and Microbial Exposure
4.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.