Physical propagation and anomaly identification of transformer with HVDC&RTTS stray current invasion

• The stray current is characterized by characteristic factors (DC factor and mutation factor). • The virtual simulation model of transformer is constructed, and the variation law of multi-field parameters is summarized. • The multi-information is obtained through dynamic experiments, and the correctness of the simulation conclusion is verified. • The instability criterion of transformer is established with characteristic factor. Aiming at the operation stability of the transformer with stray current invasion, the evolution and propagation of multiple information is investigated in this paper. Firstly, the morphological characteristics of stray current are comparatively analyzed based on the measured data. The persistence and fluctuation of the stray current are characterized by characteristic factors (DC factor and mutation factor). Then, the characteristic factors are associated with abnormal features by sequential coupling. The virtual simulation model of transformer is constructed to simulate the electromagnetic, force, vibration and noise of components, and the laws are summarized. The results show that the vibration and noise become significant with the increase of the DC factor, and the distortion of the time domain waveform becomes serious with the increase of the mutation factor. Through the dynamic experiment platform, the physical entity of the transformer is constructed, obtaining multiple information in different modes. The correctness of the conclusions is verified by the calibration of virtual-physical consistency. On this basis, the multi-mode-state characteristic information domain is formed. The mapping relationship between stray current and vibration noise is studied with characteristic factors. Meanwhile, the abnormality of multiple information can be effectively characterized with characteristic factors. The instability criterion of transformer is established and the state interval is classified, which provides ideas for life-cycle assessment and information-physical fusion of transformer.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-09-22
DOI
https://doi.org/10.1016/j.ijepes.2025.111159
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physical propagation and anomaly identification of transformer with HVDC&RTTS stray current invasion

Shasha Zou, Zhenglong Sun, Chao Pan, Tongrui Fu et al.
International Journal of Electrical Power & Energy Systems
High-Voltage Power Transmission Systems
article

Physical propagation and anomaly identification of transformer with HVDC&RTTS stray current invasion

Shasha Zou, Zhenglong Sun, Chao Pan, Tongrui Fu, Jun Gao, Jingge An
article en

Abstract

• The stray current is characterized by characteristic factors (DC factor and mutation factor). • The virtual simulation model of transformer is constructed, and the variation law of multi-field parameters is summarized. • The multi-information is obtained through dynamic experiments, and the correctness of the simulation conclusion is verified. • The instability criterion of transformer is established with characteristic factor. Aiming at the operation stability of the transformer with stray current invasion, the evolution and propagation of multiple information is investigated in this paper. Firstly, the morphological characteristics of stray current are comparatively analyzed based on the measured data. The persistence and fluctuation of the stray current are characterized by characteristic factors (DC factor and mutation factor). Then, the characteristic factors are associated with abnormal features by sequential coupling. The virtual simulation model of transformer is constructed to simulate the electromagnetic, force, vibration and noise of components, and the laws are summarized. The results show that the vibration and noise become significant with the increase of the DC factor, and the distortion of the time domain waveform becomes serious with the increase of the mutation factor. Through the dynamic experiment platform, the physical entity of the transformer is constructed, obtaining multiple information in different modes. The correctness of the conclusions is verified by the calibration of virtual-physical consistency. On this basis, the multi-mode-state characteristic information domain is formed. The mapping relationship between stray current and vibration noise is studied with characteristic factors. Meanwhile, the abnormality of multiple information can be effectively characterized with characteristic factors. The instability criterion of transformer is established and the state interval is classified, which provides ideas for life-cycle assessment and information-physical fusion of transformer.

International Journal of Electrical Power & Energy SystemsVol. 172
Northeast Electric Power University (CN)
Openalex Percentile: Top 75%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.