Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13 n e q / cm 2 to a few times 1e15 n e q / cm 2 . This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 n e q / cm 2 fluence over the lifetime of the experiment.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-09-22
DOI
https://doi.org/10.1016/j.nima.2025.171012
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of neutron and proton irradiated AC-LGAD sensors

J. Ott, J. J. Ding, A. Molnar, M. Gignac et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
article

Performance of neutron and proton irradiated AC-LGAD sensors

J. Ott, J. J. Ding, A. Molnar, M. Gignac, S. Seidel, T. Shin, B. A. Schumm, M. Wilder, Mark J. Davis, G. Kramberger, A. Seiden, Sebastian Beringer, H. F-W. Sadrozinski, S. M. Mazza, Jiahe Si, I. Mandić, R. Novotny, F. McKinney-Martinez, G. Stage, A. Borjigin
article en

Abstract

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400 MeV protons at FNAL ITA to fluences from 1e13 n e q / cm 2 to a few times 1e15 n e q / cm 2 . This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13 n e q / cm 2 fluence over the lifetime of the experiment.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1082
University of Hawaiʻi at Mānoa (US), University of New Mexico (US), University of California, Santa Cruz (US), Linac Coherent Light Source (US), Centre of Excellence NAMASTE (SI)
Openalex Percentile: Top 89%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.