Cyclic etching of SiO2 contact holes using heptafluoropropyl methyl ether having low global-warming potential

• Cyclic etching of SiO 2 holes was developed using low-GWP HFE-347mcc3 plasma. • Durations of deposition and etching steps were optimized to control etch profiles. • Degree of exposure to fluorocarbon plasma (DEF) was introduced as a key parameter. • Highly anisotropic SiO 2 contact holes with an aspect ratio of 24 were achieved. SiO 2 contact holes having high aspect ratios were etched using a cyclic-etching process employing heptafluoropropyl methyl ether (HFE-347mcc3) which exhibits a low global-warming potential (GWP ≈530) compared with conventional perfluorocarbons (PFCs) and hydrofluorocarbons (HFCs). In this cyclic process, the etching steps involving HFE-347mcc3/O 2 /Ar plasmas were alternated with deposition steps involving HFE-347mcc3/Ar plasmas to precisely control the fluorocarbon passivation films on the sidewalls. The effects of the deposition- and etching-step durations on the contact-hole profiles were systematically investigated. Increasing the duration of the deposition step initially improved sidewall protection, thereby significantly reducing bowing and enhancing anisotropy; however, excessively long deposition-step durations caused narrowing. Similarly, the duration of the etching step was optimized to achieve sufficient fluorocarbon-film hardening to prevent bowing while avoiding excessive narrowing. The degree of exposure to fluorocarbon plasma was introduced as a critical parameter to optimize the anisotropy. Under optimized conditions, a nearly vertical and highly anisotropic SiO 2 contact hole having a diameter of 100 nm and an aspect ratio of 24 was successfully obtained with minimal bowing (1 nm). The results revealed that HFE-347mcc3 is a viable and environmentally sustainable alternative to high-GWP PFCs or HFCs and provide both environmental benefits and excellent etching performance.

Authors

Institutions

Publication Details

Journal
Materials & Design
Published
2025-09-22
DOI
https://doi.org/10.1016/j.matdes.2025.114797
Citations
1
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyclic etching of SiO2 contact holes using heptafluoropropyl methyl ether having low global-warming potential

Inkyoung Cho, Chang‐Koo Kim, Junyoung Kim, Sangheon Lee
1 citations
Materials & Design
Plasma Diagnostics and Applications
0.73
article

Cyclic etching of SiO2 contact holes using heptafluoropropyl methyl ether having low global-warming potential

Inkyoung Cho, Chang‐Koo Kim, Junyoung Kim, Sangheon Lee
article en
1 citations

Abstract

• Cyclic etching of SiO 2 holes was developed using low-GWP HFE-347mcc3 plasma. • Durations of deposition and etching steps were optimized to control etch profiles. • Degree of exposure to fluorocarbon plasma (DEF) was introduced as a key parameter. • Highly anisotropic SiO 2 contact holes with an aspect ratio of 24 were achieved. SiO 2 contact holes having high aspect ratios were etched using a cyclic-etching process employing heptafluoropropyl methyl ether (HFE-347mcc3) which exhibits a low global-warming potential (GWP ≈530) compared with conventional perfluorocarbons (PFCs) and hydrofluorocarbons (HFCs). In this cyclic process, the etching steps involving HFE-347mcc3/O 2 /Ar plasmas were alternated with deposition steps involving HFE-347mcc3/Ar plasmas to precisely control the fluorocarbon passivation films on the sidewalls. The effects of the deposition- and etching-step durations on the contact-hole profiles were systematically investigated. Increasing the duration of the deposition step initially improved sidewall protection, thereby significantly reducing bowing and enhancing anisotropy; however, excessively long deposition-step durations caused narrowing. Similarly, the duration of the etching step was optimized to achieve sufficient fluorocarbon-film hardening to prevent bowing while avoiding excessive narrowing. The degree of exposure to fluorocarbon plasma was introduced as a critical parameter to optimize the anisotropy. Under optimized conditions, a nearly vertical and highly anisotropic SiO 2 contact hole having a diameter of 100 nm and an aspect ratio of 24 was successfully obtained with minimal bowing (1 nm). The results revealed that HFE-347mcc3 is a viable and environmentally sustainable alternative to high-GWP PFCs or HFCs and provide both environmental benefits and excellent etching performance.

Materials & DesignVol. 259
Ewha Womans University (KR), Ajou University (KR)
Openalex Percentile: Top 23%
Plasma Diagnostics and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines