Assessing within-individual gait acceleration variability: a comparative analysis of remote monitoring and laboratory measurements

Wearable sensor technology has revolutionized gait analysis by enabling studies in real-world settings and enhancing ecological validity. However, this shift introduces challenges due to uncontrolled environmental factors that contribute to variability, reflecting the multiple contexts in which real-world gait takes place. This study investigates the variability of gait acceleration data, collected with wearable sensors in remote settings, compared to controlled laboratory measurements, focusing on within-individual variability over time. Data were collected from two groups: ten healthy individuals who wore SENS Motion activity monitors on their thighs continuously for two weeks during daily activities, and fifty participants from an open-access gait laboratory dataset. The remote data enabled analysis of gait in natural, unsupervised settings, while the laboratory data provided a controlled comparison. Variability in acceleration time profiles across strides was analyzed using mixed-effect models, and dynamic stability was assessed through the largest Lyapunov exponent (LLE) to evaluate gait consistency and stability. The results revealed that acceleration data from the remote settings exhibited higher variability both within and between days compared to the controlled laboratory data. This increased variability was most pronounced along the anteroposterior axis, likely due to the uncontrolled nature of the remote environment. Despite this variability, the dynamic stability of the gait patterns, as measured by LLE, showed no significant differences between the two environments; however, not comparing the same individuals in both settings may have obscured potential differences in LLE. The findings suggest that while wearable sensors capture greater variability in uncontrolled environments, the underlying stability of gait patterns remains intact. The perservation of stability despite greater variability supports the use of wearable sensors for extended gait monitoring in remote settings, with potential implications for improving remote patient monitoring and understanding gait variability in clinical populations.

Authors

Institutions

Publication Details

Journal
BMC Digital Health
Published
2025-09-22
DOI
https://doi.org/10.1186/s44247-025-00179-z
Citations
1
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
4.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing within-individual gait acceleration variability: a comparative analysis of remote monitoring and laboratory measurements

John Rasmussen, Arash Ghaffari, Ole Rahbek, Reed D. Gurchiek et al.
1 citations
BMC Digital Health
Balance, Gait, and Falls Prevention
4.76
article

Assessing within-individual gait acceleration variability: a comparative analysis of remote monitoring and laboratory measurements

John Rasmussen, Arash Ghaffari, Ole Rahbek, Reed D. Gurchiek, Rasmus Waagepetersen, Søren Kold
article en
1 citations

Abstract

Wearable sensor technology has revolutionized gait analysis by enabling studies in real-world settings and enhancing ecological validity. However, this shift introduces challenges due to uncontrolled environmental factors that contribute to variability, reflecting the multiple contexts in which real-world gait takes place. This study investigates the variability of gait acceleration data, collected with wearable sensors in remote settings, compared to controlled laboratory measurements, focusing on within-individual variability over time. Data were collected from two groups: ten healthy individuals who wore SENS Motion activity monitors on their thighs continuously for two weeks during daily activities, and fifty participants from an open-access gait laboratory dataset. The remote data enabled analysis of gait in natural, unsupervised settings, while the laboratory data provided a controlled comparison. Variability in acceleration time profiles across strides was analyzed using mixed-effect models, and dynamic stability was assessed through the largest Lyapunov exponent (LLE) to evaluate gait consistency and stability. The results revealed that acceleration data from the remote settings exhibited higher variability both within and between days compared to the controlled laboratory data. This increased variability was most pronounced along the anteroposterior axis, likely due to the uncontrolled nature of the remote environment. Despite this variability, the dynamic stability of the gait patterns, as measured by LLE, showed no significant differences between the two environments; however, not comparing the same individuals in both settings may have obscured potential differences in LLE. The findings suggest that while wearable sensors capture greater variability in uncontrolled environments, the underlying stability of gait patterns remains intact. The perservation of stability despite greater variability supports the use of wearable sensors for extended gait monitoring in remote settings, with potential implications for improving remote patient monitoring and understanding gait variability in clinical populations.

BMC Digital HealthVol. 3(1)
Aalborg University Hospital (DK), Clemson University (US), Aalborg University (DK)
Openalex Percentile: Top 6%
Balance, Gait, and Falls Prevention
4.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.