Lens design strategies for miniature scanning fiber endoscopes

This paper provides guidance for the illumination configuration optical design of scanning fiber endoscopes (SFEs), offering insights into salient optical principles and relevant optical system properties, as well as trade-offs and considerations necessary for achieving the desired image performance in miniature endoscopic systems. The specific design examined is a piezoelectric scanner tube-based cantilevered SFE with a concentrically mounted, cantilevered single mode fiber. The assumption of monochromaticity is made for simplicity. Example designs are provided, simulated in Ansys Zemax OpticStudio. The purpose of this guide is to assist designers who may have limited optical design experience by addressing each phase of the SFE design process, from fiber oscillation modeling to optical element selection. Beginning with the motivation for utilizing SFE and introduction of design principles, the guide then describes appropriate approximations for the object, in this case the light emitted from the tip of the scanning fiber over its scanning range (including deflection, sag, and normal angle). Important optical system properties are described, including optical system length, working distance, field of view, throughput, magnification, common aberrations, resolution, and depth of focus, as well as cost. Example optical designs are then modeled in Ansys Zemax OpticStudio, to illustrate common trade-offs in optical performance. The examples are separated into two main categories, variable magnification systems, and fixed magnification systems. Both variable and fixed magnification designs start from a paraxial pre-design followed by a one utilizing real commercial off the shelf (COTS) lenses, both conventional and gradient index (GRIN) lenses. A final design provides an example of optimizing performance priorities utilizing a hybrid of COTS and custom elements. This guide provides the design steps and starting points needed to create an intuitive and well-performing SFE optical design.

Authors

Institutions

Publication Details

Journal
Optical Engineering
Published
2025-09-22
DOI
https://doi.org/10.1117/1.oe.64.9.090801
Primary Topic
Advanced optical system design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lens design strategies for miniature scanning fiber endoscopes

Alana Gonzales, Dominique Galvez, Jennifer K. Barton, Eduardo González et al.
Optical Engineering
Advanced optical system design
article

Lens design strategies for miniature scanning fiber endoscopes

Alana Gonzales, Dominique Galvez, Jennifer K. Barton, Eduardo González, Andrew D. Rocha, Matthias Schlich, David Vega
article en

Abstract

This paper provides guidance for the illumination configuration optical design of scanning fiber endoscopes (SFEs), offering insights into salient optical principles and relevant optical system properties, as well as trade-offs and considerations necessary for achieving the desired image performance in miniature endoscopic systems. The specific design examined is a piezoelectric scanner tube-based cantilevered SFE with a concentrically mounted, cantilevered single mode fiber. The assumption of monochromaticity is made for simplicity. Example designs are provided, simulated in Ansys Zemax OpticStudio. The purpose of this guide is to assist designers who may have limited optical design experience by addressing each phase of the SFE design process, from fiber oscillation modeling to optical element selection. Beginning with the motivation for utilizing SFE and introduction of design principles, the guide then describes appropriate approximations for the object, in this case the light emitted from the tip of the scanning fiber over its scanning range (including deflection, sag, and normal angle). Important optical system properties are described, including optical system length, working distance, field of view, throughput, magnification, common aberrations, resolution, and depth of focus, as well as cost. Example optical designs are then modeled in Ansys Zemax OpticStudio, to illustrate common trade-offs in optical performance. The examples are separated into two main categories, variable magnification systems, and fixed magnification systems. Both variable and fixed magnification designs start from a paraxial pre-design followed by a one utilizing real commercial off the shelf (COTS) lenses, both conventional and gradient index (GRIN) lenses. A final design provides an example of optimizing performance priorities utilizing a hybrid of COTS and custom elements. This guide provides the design steps and starting points needed to create an intuitive and well-performing SFE optical design.

Optical EngineeringVol. 64(09)
University of Arizona (US), Ansys (United States) (US), Optics Technology (United States) (US)
Openalex Percentile: Top 75%
Advanced optical system design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.