Primary Anterior Conjunctival Cyst Developed Over an Encapsulated Ahmed® Glaucoma Valve Device: A Case Report

Background Several studies have recommended glaucoma drainage devices (GDDs), particularly the use of the Ahmed glaucoma valve, as the primary surgical procedure. Nevertheless, surgical hypotony, capsular fibrosis, and tube failure are among the side effects of these devices. In this study, we report a case of the development of a conjunctival cyst as a complication of the surgical implantation of the Ahmed glaucoma valve device. Case Presentation A 21-year-old man who was diagnosed with bilateral congenital glaucoma presented with a persistently high intraocular pressure even after undergoing bilateral trabeculectomy and trabeculotomy with mitomycin C. After that, Ahmed glaucoma valve was employed, which led to an improvement in IOP postoperatively; however, upon follow-up, we noticed by clinical examination the development of a large encapsulated subconjunctival cyst, and then prompt surgical excision of the cyst was performed. Conclusion Formation of a large conjunctival cyst is one of the complications that can be noticed post-AGV (Ahmed® glaucoma valve) use. This case showed the surgical resection of the cyst to be essential and effective. More investigations are needed to address this complication with proper preoperative counselling for any postoperative GGD complications occurring in the patients.

Authors

Institutions

Publication Details

Journal
The Open Ophthalmology Journal
Published
2025-09-12
DOI
https://doi.org/10.2174/0118743641409090250911061303
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Primary Anterior Conjunctival Cyst Developed Over an Encapsulated Ahmed® Glaucoma Valve Device: A Case Report

Abdullah Alkandari, Mohammed Ghazi Alsaedi, Sami Al-Shahwan, Khaled Saleh Alharthi
The Open Ophthalmology Journal
Glaucoma and retinal disorders
article

Primary Anterior Conjunctival Cyst Developed Over an Encapsulated Ahmed® Glaucoma Valve Device: A Case Report

Abdullah Alkandari, Mohammed Ghazi Alsaedi, Sami Al-Shahwan, Khaled Saleh Alharthi
article en

Abstract

Background Several studies have recommended glaucoma drainage devices (GDDs), particularly the use of the Ahmed glaucoma valve, as the primary surgical procedure. Nevertheless, surgical hypotony, capsular fibrosis, and tube failure are among the side effects of these devices. In this study, we report a case of the development of a conjunctival cyst as a complication of the surgical implantation of the Ahmed glaucoma valve device. Case Presentation A 21-year-old man who was diagnosed with bilateral congenital glaucoma presented with a persistently high intraocular pressure even after undergoing bilateral trabeculectomy and trabeculotomy with mitomycin C. After that, Ahmed glaucoma valve was employed, which led to an improvement in IOP postoperatively; however, upon follow-up, we noticed by clinical examination the development of a large encapsulated subconjunctival cyst, and then prompt surgical excision of the cyst was performed. Conclusion Formation of a large conjunctival cyst is one of the complications that can be noticed post-AGV (Ahmed® glaucoma valve) use. This case showed the surgical resection of the cyst to be essential and effective. More investigations are needed to address this complication with proper preoperative counselling for any postoperative GGD complications occurring in the patients.

The Open Ophthalmology JournalVol. 19(1)
Farwaniya Hospital (KW), King Abdulaziz Medical City (SA), King Khaled Eye Specialist Hospital (SA), King Abdulaziz Hospital (SA)
Openalex Percentile: Top 62%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Primary Anterior Conjunctival Cyst Developed Over an Encapsulated Ahmed® Glaucoma Valve Device: A Case Report — Abdullah Alkandari, Mohammed Ghazi Alsaedi, et al. · The Open Ophthalmology Journal (2025) | TGRS Research Map | TGRS