Test and Analysis of Lateral-Offset Optical Fiber Mach-Zehnder Interferometer Using Near-Infrared Light Employed as Chloride Ion Concentration Sensor

This paper presents a test and analysis of a lateral-offset optical fiber Mach-Zehnder interferometer (MZI) employed as a chloride ion concentration sensor using a near-infrared light source (amplified spontaneous emission, wavelength = 1520–1620 nm). An 8 cm optical fiber MZI sensor was fabricated and fusion-spliced using a lateral-offset process. We used this 8 cm lateral-offset optical fiber MZI to measure chloride ions in samples of sodium chloride solutions with different weight concentrations ranging from 0.015% to 25% and then analyzed the interference spectra regarding their normalized intensity and wavelength shift and three integral area ranges (1520–1580 nm, 1540–1600 nm, and 1520–1620 nm). The comparative spectral analysis results show that the lateral-offset optical fiber MZI sensor exhibited a linear decrease in its normalized intensity as well as a wavelength shift when the concentration increased. The lateral-offset optical fiber MZI sensor displayed a sine wave plot in the three integral area ranges when the concentration increased. Other than sensing parameters such as the normalized intensity (adjusted R-squared = 0.98223) or wavelength shift (adjusted R-squared = 0.94209), the three integral area ranges (adjusted R-squared = 0.96425, 0.91621, and 0.9577, respectively), which possessed adjusted R-squared values greater than 0.9, are also recommended for use as sensing parameters for the testing and analysis of a lateral-offset optical fiber MZI employed as a chloride ion concentration sensor using a near-infrared light source.

Authors

Institutions

Publication Details

Published
2025-09-12
DOI
https://doi.org/10.3390/proceedings2025129073
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test and Analysis of Lateral-Offset Optical Fiber Mach-Zehnder Interferometer Using Near-Infrared Light Employed as Chloride Ion Concentration Sensor

Peter H. Wu, Jian-Neng Wang
Advanced Fiber Optic Sensors
article

Test and Analysis of Lateral-Offset Optical Fiber Mach-Zehnder Interferometer Using Near-Infrared Light Employed as Chloride Ion Concentration Sensor

Peter H. Wu, Jian-Neng Wang
article en

Abstract

This paper presents a test and analysis of a lateral-offset optical fiber Mach-Zehnder interferometer (MZI) employed as a chloride ion concentration sensor using a near-infrared light source (amplified spontaneous emission, wavelength = 1520–1620 nm). An 8 cm optical fiber MZI sensor was fabricated and fusion-spliced using a lateral-offset process. We used this 8 cm lateral-offset optical fiber MZI to measure chloride ions in samples of sodium chloride solutions with different weight concentrations ranging from 0.015% to 25% and then analyzed the interference spectra regarding their normalized intensity and wavelength shift and three integral area ranges (1520–1580 nm, 1540–1600 nm, and 1520–1620 nm). The comparative spectral analysis results show that the lateral-offset optical fiber MZI sensor exhibited a linear decrease in its normalized intensity as well as a wavelength shift when the concentration increased. The lateral-offset optical fiber MZI sensor displayed a sine wave plot in the three integral area ranges when the concentration increased. Other than sensing parameters such as the normalized intensity (adjusted R-squared = 0.98223) or wavelength shift (adjusted R-squared = 0.94209), the three integral area ranges (adjusted R-squared = 0.96425, 0.91621, and 0.9577, respectively), which possessed adjusted R-squared values greater than 0.9, are also recommended for use as sensing parameters for the testing and analysis of a lateral-offset optical fiber MZI employed as a chloride ion concentration sensor using a near-infrared light source.

National Yunlin University of Science and Technology (TW)
Openalex Percentile: Top 75%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.