Development of a Portable Calibration Chamber for PM Sensors Equipped with Wireless Connectivity Controlled by a Graphical Interface in Python

The health impact of air pollutants has generated a trend in the design and manufacture of portable, personal and fixed PM monitoring systems to help reduce exposure to air pollutants. However, these devices still need to be improved and properly evaluated to compete with environmental monitors in the market. In this work, a test chamber with controlled environmental conditions and wireless connectivity is developed for the evaluation of low-cost portable and personal PM sensors. The developed system ensures rapid evaluation tests ranging from seconds to hours to corroborate prolonged operation and correct calibration. The system is controlled by a Python-based graphical user interface (GUI) and monitors PM concentration, altitude, relative humidity, atmospheric pressure, illuminance, and temperature measurements. Fifty measurement tests with a duration of 10 min each were conducted to ensure robust performance and data transfer. Subsequently, four calibration tests were conducted using two SENSIRION SPS30 (SPS A and SPS B) personal PM sensors and two PMS5003 (PMS A and PMS B) personal PM sensors. The Prana Air PAS-OUT-01 sensor served as the reference to calculate the correlations and the descriptive statistics between each sensor to be calibrated. A contamination source was employed utilizing a monodispersed aerosol generator for 0.46 µm latex polystyrene particle atomization. Linear regression was applied during the calibration to determine the calibration coefficients, which were then used to adjust the sensor readings in the respective code and descriptive statistics of the sensor calibration tests were calculated. For the PMS5003 sensors, the Pearson correlation coefficients (r) after calibration were PMS A: 0.9870 and PMS B: 0.9898 compared to their uncalibrated values of PMS A: 0.9828 and PMS B: 0.9863. In contrast, the uncalibrated SPS A sensor initially had a correlation of 0.9939, which slightly decreased to 0.9917 after calibration. Meanwhile, the uncalibrated SPS B sensor showed a correlation of 0.9422, which improved to 0.9715 after calibration.

Authors

Institutions

Publication Details

Journal
Environments
Published
2025-09-21
DOI
https://doi.org/10.3390/environments12090338
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Portable Calibration Chamber for PM Sensors Equipped with Wireless Connectivity Controlled by a Graphical Interface in Python

Marco A. Reyna, Roberto L. Avitia, Eladio Altamira-Colado, Daniel Cuevas-González et al.
Environments
Gas Sensing Nanomaterials and Sensors
article

Development of a Portable Calibration Chamber for PM Sensors Equipped with Wireless Connectivity Controlled by a Graphical Interface in Python

Marco A. Reyna, Roberto L. Avitia, Eladio Altamira-Colado, Daniel Cuevas-González, Martín Aarón Sánchez-Barajas, Juan Pablo Garćıa-Vázquez
article en

Abstract

The health impact of air pollutants has generated a trend in the design and manufacture of portable, personal and fixed PM monitoring systems to help reduce exposure to air pollutants. However, these devices still need to be improved and properly evaluated to compete with environmental monitors in the market. In this work, a test chamber with controlled environmental conditions and wireless connectivity is developed for the evaluation of low-cost portable and personal PM sensors. The developed system ensures rapid evaluation tests ranging from seconds to hours to corroborate prolonged operation and correct calibration. The system is controlled by a Python-based graphical user interface (GUI) and monitors PM concentration, altitude, relative humidity, atmospheric pressure, illuminance, and temperature measurements. Fifty measurement tests with a duration of 10 min each were conducted to ensure robust performance and data transfer. Subsequently, four calibration tests were conducted using two SENSIRION SPS30 (SPS A and SPS B) personal PM sensors and two PMS5003 (PMS A and PMS B) personal PM sensors. The Prana Air PAS-OUT-01 sensor served as the reference to calculate the correlations and the descriptive statistics between each sensor to be calibrated. A contamination source was employed utilizing a monodispersed aerosol generator for 0.46 µm latex polystyrene particle atomization. Linear regression was applied during the calibration to determine the calibration coefficients, which were then used to adjust the sensor readings in the respective code and descriptive statistics of the sensor calibration tests were calculated. For the PMS5003 sensors, the Pearson correlation coefficients (r) after calibration were PMS A: 0.9870 and PMS B: 0.9898 compared to their uncalibrated values of PMS A: 0.9828 and PMS B: 0.9863. In contrast, the uncalibrated SPS A sensor initially had a correlation of 0.9939, which slightly decreased to 0.9917 after calibration. Meanwhile, the uncalibrated SPS B sensor showed a correlation of 0.9422, which improved to 0.9715 after calibration.

EnvironmentsVol. 12(9)
Universidad Autónoma de Baja California (MX), Mexicali Institute of Technology (MX), Tecnológico Nacional de México (MX)
Universidad Autónoma de Baja California
Openalex Percentile: Top 75%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.