The Feasibility of Combining 3D Cine bSSFP and 4D Flow MRI for the Assessment of Local Aortic Pulse Wave Velocity

Pulse wave velocity (PWV) is a key marker of aortic stiffness and cardiovascular risk, yet current methods typically offer only global or regional estimates and lack the possibility to measure local variations along the thoracic aorta. This study aimed to develop and evaluate a pipeline for assessing local aortic PWV using the flow–area (QA) method (PWVQA) by combining high-resolution 4D MRI techniques. A 3D cine balanced steady-state free precession (bSSFP) sequence was used to capture dynamic changes in aortic geometry, while 4D flow MRI measured time-resolved blood flow. The QA method was applied during the reflection-free early systolic phase. Scan–rescan reproducibility was assessed in six healthy volunteers, and feasibility was additionally explored in Marfan syndrome patients. The mean ± SD values of the Pearson correlation coefficients for per-slice maximum area, velocity, flow, and PWVQA were 0.99 ± 0.00, 0.82 ± 0.11, 0.96 ± 0.01, and 0.20 ± 0.35, respectively. The median (Q1–Q3) average PWVQA was 6.6 (5.4–9.4) m/s for scan 1 and 9.1 (6.7–11.3) m/s for scan 2 (p = 0.16) in healthy volunteers and 7.1 (6.9–8.0) m/s in Marfan patients. Combining 4D bSSFP and 4D flow MRI is technically feasible, but the derived PWVQA maps show high variability, particularly in the aortic root and descending aorta, requiring further optimization.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-09-21
DOI
https://doi.org/10.3390/app151810272
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Feasibility of Combining 3D Cine bSSFP and 4D Flow MRI for the Assessment of Local Aortic Pulse Wave Velocity

Eric Schrauben, Pim van Ooij, Gustav J. Strijkers, Aart J. Nederveen et al.
Applied Sciences
Cardiovascular Health and Disease Prevention
article

The Feasibility of Combining 3D Cine bSSFP and 4D Flow MRI for the Assessment of Local Aortic Pulse Wave Velocity

Eric Schrauben, Pim van Ooij, Gustav J. Strijkers, Aart J. Nederveen, Daan Bosshardt, Renske Merton
article en

Abstract

Pulse wave velocity (PWV) is a key marker of aortic stiffness and cardiovascular risk, yet current methods typically offer only global or regional estimates and lack the possibility to measure local variations along the thoracic aorta. This study aimed to develop and evaluate a pipeline for assessing local aortic PWV using the flow–area (QA) method (PWVQA) by combining high-resolution 4D MRI techniques. A 3D cine balanced steady-state free precession (bSSFP) sequence was used to capture dynamic changes in aortic geometry, while 4D flow MRI measured time-resolved blood flow. The QA method was applied during the reflection-free early systolic phase. Scan–rescan reproducibility was assessed in six healthy volunteers, and feasibility was additionally explored in Marfan syndrome patients. The mean ± SD values of the Pearson correlation coefficients for per-slice maximum area, velocity, flow, and PWVQA were 0.99 ± 0.00, 0.82 ± 0.11, 0.96 ± 0.01, and 0.20 ± 0.35, respectively. The median (Q1–Q3) average PWVQA was 6.6 (5.4–9.4) m/s for scan 1 and 9.1 (6.7–11.3) m/s for scan 2 (p = 0.16) in healthy volunteers and 7.1 (6.9–8.0) m/s in Marfan patients. Combining 4D bSSFP and 4D flow MRI is technically feasible, but the derived PWVQA maps show high variability, particularly in the aortic root and descending aorta, requiring further optimization.

Applied SciencesVol. 15(18)
University of Amsterdam (NL)
Openalex Percentile: Top 61%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Feasibility of Combining 3D Cine bSSFP and 4D Flow MRI for the Assessment of Local Aortic Pulse Wave Velocity — Eric Schrauben, Pim van Ooij, et al. · Applied Sciences (2025) | TGRS Research Map | TGRS