High-Temperature and Acid Resistance of Concrete with Recycled, Desert Sand, and Crumb Rubber Blends

Natural sand extraction for concrete manufacturing is a global issue for ecological balance and environmental concerns. This study introduced three mixes with three newly developed sand types to replace natural sand in concrete manufacturing. Additionally, three more mixes were made by incorporating optimized 10% silica fume. The durability of the prepared mixes was evaluated at high temperatures of (150-750 °C) at the interval of 150 °C and against immersion in a 5% sulfuric acid solution for 28, 56, 91, and 182 days, respectively. The study's results reported the stability of the samples up to 300 °C, and then the fall of the samples started at 450 °C. Severe damage in the samples was formed at about 600 °C, and finally, a total collapse was seen at 750 °C. From (150 to 750 °C), the mix TYPE-3SSFC with a sustainable sand combination (50% recycled sand + 45% desert sand + 5% crumb rubber) and 10% silica fume showed better resistance than the other mixes. The compressive strength in the mix TYPE-3SSFC was 20.6%, 16.3%, 14.7%, 21.3%, 26.5%, and 43.2% higher than the mix TYPE-3SC with 10% silica fume. The mix TYPE-3SSFC with optimized 10% silica fume content showed better resistance against 5% sulfuric acid solution than those without silica fume. By morphological analysis, the mix TYPE-3SSFC showed that the interface improved due to the dense interconnectivity of the concrete mix between the crumb rubber paste and silica fume content. A dense calcite crystal was also seen in the mixture, which confirmed the study's results. The mix with TYPE 2-Sand (100% recycled sand) revealed inferior results, low stability, and high damage. Thus, 100% recycled sand is not recommended for structural concrete.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-09-22
DOI
https://doi.org/10.3390/ma18184410
Citations
1
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Temperature and Acid Resistance of Concrete with Recycled, Desert Sand, and Crumb Rubber Blends

Mohammad Nadeem Akhtar, Khaldoon A. Bani-Hani, Jan Nisar Akhtar
1 citations
Materials
Recycled Aggregate Concrete Performance
1.01
article

High-Temperature and Acid Resistance of Concrete with Recycled, Desert Sand, and Crumb Rubber Blends

Mohammad Nadeem Akhtar, Khaldoon A. Bani-Hani, Jan Nisar Akhtar
article en
1 citations

Abstract

Natural sand extraction for concrete manufacturing is a global issue for ecological balance and environmental concerns. This study introduced three mixes with three newly developed sand types to replace natural sand in concrete manufacturing. Additionally, three more mixes were made by incorporating optimized 10% silica fume. The durability of the prepared mixes was evaluated at high temperatures of (150-750 °C) at the interval of 150 °C and against immersion in a 5% sulfuric acid solution for 28, 56, 91, and 182 days, respectively. The study's results reported the stability of the samples up to 300 °C, and then the fall of the samples started at 450 °C. Severe damage in the samples was formed at about 600 °C, and finally, a total collapse was seen at 750 °C. From (150 to 750 °C), the mix TYPE-3SSFC with a sustainable sand combination (50% recycled sand + 45% desert sand + 5% crumb rubber) and 10% silica fume showed better resistance than the other mixes. The compressive strength in the mix TYPE-3SSFC was 20.6%, 16.3%, 14.7%, 21.3%, 26.5%, and 43.2% higher than the mix TYPE-3SC with 10% silica fume. The mix TYPE-3SSFC with optimized 10% silica fume content showed better resistance against 5% sulfuric acid solution than those without silica fume. By morphological analysis, the mix TYPE-3SSFC showed that the interface improved due to the dense interconnectivity of the concrete mix between the crumb rubber paste and silica fume content. A dense calcite crystal was also seen in the mixture, which confirmed the study's results. The mix with TYPE 2-Sand (100% recycled sand) revealed inferior results, low stability, and high damage. Thus, 100% recycled sand is not recommended for structural concrete.

MaterialsVol. 18(18)
Aligarh Muslim University (IN), Fahd bin Sultan University (SA)
Openalex Percentile: Top 20%
Recycled Aggregate Concrete Performance
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Temperature and Acid Resistance of Concrete with Recycled, Desert Sand, and Crumb Rubber Blends — Mohammad Nadeem Akhtar, Khaldoon A. Bani-Hani, et al. · Materials (2025) | TGRS Research Map | TGRS