A Study on the Optimization Design of Power System Winding Structure Equipment Based on NSGA-II

As a key component for maintaining the efficient and stable operation of flexible DC transmission systems, the arm reactor often suffers from uneven loss distribution and localized overheating in its windings due to the superimposed AC and DC currents, which adversely affects its operational lifespan. Furthermore, arm reactors are frequently deployed in offshore environments for long-distance, high-capacity power transmission, imposing additional requirements on energy utilization efficiency and seismic resistance. To address these challenges, this study proposes an optimization design method for arm reactors based on a triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise,” aiming to achieve “low loss–low temperature rise–low weight.” First, an equivalent electromagnetic model of the arm reactor under combined AC and DC operating conditions is established to analytically calculate the self- and mutual-inductance-distribution characteristics between winding layers and the loss distribution across windings. The calculated losses are then applied as heat sources in a fluid–thermal coupling method to compute the temperature field of the arm reactor. Next, leveraging a Kriging surrogate model to capture the relationship between the winding temperature rise in the bridge-arm reactor and the loss density, encapsulation width, encapsulation height, and air duct width, the revised analytical expression reduces the temperature rise error from 43.74% to 11.47% compared with the traditional empirical formula. Finally, the triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise” is proposed to balance interlayer current distribution, suppress total loss generation, and limit localized hotspot formation. A prototype constructed based on the optimized design demonstrates a 44.51% reduction in total loss, a 39.66% decrease in hotspot temperature rise, and a 24.83% reduction in mass while maintaining rated inductance, validating the effectiveness of the proposed design algorithm.

Authors

Publication Details

Journal
Energies
Published
2025-09-20
DOI
https://doi.org/10.3390/en18185001
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Optimization Design of Power System Winding Structure Equipment Based on NSGA-II

Mengzhao Zhu, Longlong Li, Zhu Qingdong, Jian Wang et al.
Energies
Engineering Applied Research
article

A Study on the Optimization Design of Power System Winding Structure Equipment Based on NSGA-II

Mengzhao Zhu, Longlong Li, Zhu Qingdong, Jian Wang, Xuelei Wang, Zhaoliang Gu
article en

Abstract

As a key component for maintaining the efficient and stable operation of flexible DC transmission systems, the arm reactor often suffers from uneven loss distribution and localized overheating in its windings due to the superimposed AC and DC currents, which adversely affects its operational lifespan. Furthermore, arm reactors are frequently deployed in offshore environments for long-distance, high-capacity power transmission, imposing additional requirements on energy utilization efficiency and seismic resistance. To address these challenges, this study proposes an optimization design method for arm reactors based on a triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise,” aiming to achieve “low loss–low temperature rise–low weight.” First, an equivalent electromagnetic model of the arm reactor under combined AC and DC operating conditions is established to analytically calculate the self- and mutual-inductance-distribution characteristics between winding layers and the loss distribution across windings. The calculated losses are then applied as heat sources in a fluid–thermal coupling method to compute the temperature field of the arm reactor. Next, leveraging a Kriging surrogate model to capture the relationship between the winding temperature rise in the bridge-arm reactor and the loss density, encapsulation width, encapsulation height, and air duct width, the revised analytical expression reduces the temperature rise error from 43.74% to 11.47% compared with the traditional empirical formula. Finally, the triple-constraint mechanism of “equal resistive voltage–equal loss density–equal encapsulation temperature rise” is proposed to balance interlayer current distribution, suppress total loss generation, and limit localized hotspot formation. A prototype constructed based on the optimized design demonstrates a 44.51% reduction in total loss, a 39.66% decrease in hotspot temperature rise, and a 24.83% reduction in mass while maintaining rated inductance, validating the effectiveness of the proposed design algorithm.

EnergiesVol. 18(18)
Openalex Percentile: Top 73%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.