A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications

This article introduces a novel, cost-effective, noninvasive sensing mechanism for measuring water flow rate. It employs two tunneling magnetoresistance (TMR) sensors (analog and bi-polar), a magnet, and a stainless-steel cantilever. The TMR sensors are installed outside the insulating water pipe. A magnet is fixed at the free end of the cantilever and integrated into the pipe system. The cantilever's deflection corresponds to the flow rate, with an analog TMR sensor measuring the bending angle. This bending angle, in either direction of the cantilever's deflection, is captured through the analog voltage from the TMR sensor. The output from the analog TMR sensor is an analog voltage that directly reflects the strength of the magnetic field. An ESP32 microcontroller records the voltage from the analog TMR sensor, converts it to flow rates, and utilizes the bi-polar TMR sensor to ascertain the flow direction. A prototype sensor was developed and tested in a laboratory-scale setup to validate the effectiveness of the sensing mechanism. This prototype demonstrated a worst-case accuracy of 1.0% across flow rates of 0 to 1.5 m<sup>3</sup>/h for both the forward and reverse flow directions. The response and recovery times of the sensor are approximately 470 ms and 592 ms for forward and 487 ms and 625 ms for reverse direction flow. Also, hysteresis errors of 1.84% and 2.06% have been calculated for both flow directions. Notably, the sensing element does not contain any rotating components or require electrical connections to the cantilever for measurement. These attributes potentially lead to lower maintenance requirements and a longer lifespan for the sensor.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-22
DOI
https://doi.org/10.3390/s25185915
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications

Anwar Ulla Khan, Ateyah Alzahrani
Sensors
Flow Measurement and Analysis
article

A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications

Anwar Ulla Khan, Ateyah Alzahrani
article en

Abstract

This article introduces a novel, cost-effective, noninvasive sensing mechanism for measuring water flow rate. It employs two tunneling magnetoresistance (TMR) sensors (analog and bi-polar), a magnet, and a stainless-steel cantilever. The TMR sensors are installed outside the insulating water pipe. A magnet is fixed at the free end of the cantilever and integrated into the pipe system. The cantilever's deflection corresponds to the flow rate, with an analog TMR sensor measuring the bending angle. This bending angle, in either direction of the cantilever's deflection, is captured through the analog voltage from the TMR sensor. The output from the analog TMR sensor is an analog voltage that directly reflects the strength of the magnetic field. An ESP32 microcontroller records the voltage from the analog TMR sensor, converts it to flow rates, and utilizes the bi-polar TMR sensor to ascertain the flow direction. A prototype sensor was developed and tested in a laboratory-scale setup to validate the effectiveness of the sensing mechanism. This prototype demonstrated a worst-case accuracy of 1.0% across flow rates of 0 to 1.5 m<sup>3</sup>/h for both the forward and reverse flow directions. The response and recovery times of the sensor are approximately 470 ms and 592 ms for forward and 487 ms and 625 ms for reverse direction flow. Also, hysteresis errors of 1.84% and 2.06% have been calculated for both flow directions. Notably, the sensing element does not contain any rotating components or require electrical connections to the cantilever for measurement. These attributes potentially lead to lower maintenance requirements and a longer lifespan for the sensor.

SensorsVol. 25(18)
Umm al-Qura University (SA), Jazan University (SA)
Openalex Percentile: Top 71%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.