Mitigation of Magnetic Field Levels in Bipolar Transmission Lines of 500 and 600 kV in HVDC

High-Voltage Direct Current (HVDC) systems are transforming the global energy landscape, distinguished by their efficiency, stability, and low impact on the electrical grid. One of the challenges of HVDC transmission line design is assessing the generated stray magnetic field, as it can have negative effects on human health and the environment. This study presents an analytical methodology for calculating the magnetic field density at any point along an HVDC line corridor. It considers the spatial configuration, the current per pole, and the location of the conductors. The equations allow for the calculation of the horizontal and vertical components of the field, as well as its total magnitude. A practical case study of a ±500 and ±600 kV HVDC two-pole transmission line is presented. The methodology was programmed in MATLAB® version R2024a to calculate the magnetic field density, and the results are consistent with those obtained with the established methodology. The presented methodology can be applied to monopolar and two-pole HVDC overhead transmission lines, offering speed and accuracy.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-09-22
DOI
https://doi.org/10.3390/en18185022
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation of Magnetic Field Levels in Bipolar Transmission Lines of 500 and 600 kV in HVDC

Jorge Marin, Hugo Saldarriaga-Noreña, L. Cisneros-Villalobos, J. G. Vera-Dimas et al.
1 citations
Energies
HVDC Systems and Fault Protection
0.73
article

Mitigation of Magnetic Field Levels in Bipolar Transmission Lines of 500 and 600 kV in HVDC

Jorge Marin, Hugo Saldarriaga-Noreña, L. Cisneros-Villalobos, J. G. Vera-Dimas, Hurtado Alba Gutierrez, Jorge Sánchez Jaime
article en
1 citations

Abstract

High-Voltage Direct Current (HVDC) systems are transforming the global energy landscape, distinguished by their efficiency, stability, and low impact on the electrical grid. One of the challenges of HVDC transmission line design is assessing the generated stray magnetic field, as it can have negative effects on human health and the environment. This study presents an analytical methodology for calculating the magnetic field density at any point along an HVDC line corridor. It considers the spatial configuration, the current per pole, and the location of the conductors. The equations allow for the calculation of the horizontal and vertical components of the field, as well as its total magnitude. A practical case study of a ±500 and ±600 kV HVDC two-pole transmission line is presented. The methodology was programmed in MATLAB® version R2024a to calculate the magnetic field density, and the results are consistent with those obtained with the established methodology. The presented methodology can be applied to monopolar and two-pole HVDC overhead transmission lines, offering speed and accuracy.

EnergiesVol. 18(18)
Instituto Tecnológico de Toluca (MX), Universidad Autónoma del Estado de Morelos (MX)
Openalex Percentile: Top 23%
HVDC Systems and Fault Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.