Multisignal Amplification On–Off–On Strategy via Integrating the Pore Release of Polymetallic MOFs with Perovskite QDs to Induce Dual Photocurrent Polarity Reversals for an Ultrasensitive and Wide-Range Photoelectrochemical Precise Assay

A multisignal amplification on-off-on strategy was designed to facilitate a swift and accurate photoelectrochemical (PEC) assay of cardiac troponin I (cTnI), a biomarker universally acknowledged as the "gold standard" for diagnosing acute myocardial infarction (AMI). This approach combined the pore-channel release of polymetallic MOFs with the exceptional PEC properties of perovskite QDs. Hemin was encapsulated within pores of CuRu MOFs, while aptamers were immobilized on the CuRu MOF surface via electrostatic forces, effectively blocking pore channels. Upon the introduction of cTnI, the aptamers specifically bound to it and dissociated from the CuRu MOF surface, thereby enabling the efficient release of Hemin from the pore channels of CuRu MOFs even at low cTnI concentrations. Consequently, an amplified reversal response of stable cathodic photocurrent was generated, leading to a significantly reduced detection limit. The attachment of biofunctionalized Cs<sub>3</sub>Bi<sub>2</sub>Br<sub>9</sub> QDs triggered a secondary cooperative signal inversion to produce an anodic photocurrent, further amplifying the PEC response. Through these novel design elements, a multisignal amplification on-off-on assay platform was successfully constructed by inducing dual photocurrent polarity reversals. This unique signal amplification not only significantly enhanced the sensitivity (a low detection limit of 4.3 pg/mL) but also remarkably extended the linear range (5 pg/mL to 10 μg/mL) across 6.5 orders of magnitude. Such performance proved to be highly suitable for the direct and accurate quantification of cTnI in serum samples from AMI patients without the need for dilution. As a result, the proposed method enabled a clear differentiation between positive and negative clinical samples, thereby substantially expanding the application potential of analytical chemistry in clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-09-22
DOI
https://doi.org/10.1021/acs.analchem.5c04899
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multisignal Amplification On–Off–On Strategy via Integrating the Pore Release of Polymetallic MOFs with Perovskite QDs to Induce Dual Photocurrent Polarity Reversals for an Ultrasensitive and Wide-Range Photoelectrochemical Precise Assay

Zhihui H. Dai, Dongdong Xu, Wen‐Ming Wan, Jiuying Cui et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

Multisignal Amplification On–Off–On Strategy via Integrating the Pore Release of Polymetallic MOFs with Perovskite QDs to Induce Dual Photocurrent Polarity Reversals for an Ultrasensitive and Wide-Range Photoelectrochemical Precise Assay

Zhihui H. Dai, Dongdong Xu, Wen‐Ming Wan, Jiuying Cui, Wenwen Tu, Yuan Zhong, Xin Xiang
article en

Abstract

A multisignal amplification on-off-on strategy was designed to facilitate a swift and accurate photoelectrochemical (PEC) assay of cardiac troponin I (cTnI), a biomarker universally acknowledged as the "gold standard" for diagnosing acute myocardial infarction (AMI). This approach combined the pore-channel release of polymetallic MOFs with the exceptional PEC properties of perovskite QDs. Hemin was encapsulated within pores of CuRu MOFs, while aptamers were immobilized on the CuRu MOF surface via electrostatic forces, effectively blocking pore channels. Upon the introduction of cTnI, the aptamers specifically bound to it and dissociated from the CuRu MOF surface, thereby enabling the efficient release of Hemin from the pore channels of CuRu MOFs even at low cTnI concentrations. Consequently, an amplified reversal response of stable cathodic photocurrent was generated, leading to a significantly reduced detection limit. The attachment of biofunctionalized Cs<sub>3</sub>Bi<sub>2</sub>Br<sub>9</sub> QDs triggered a secondary cooperative signal inversion to produce an anodic photocurrent, further amplifying the PEC response. Through these novel design elements, a multisignal amplification on-off-on assay platform was successfully constructed by inducing dual photocurrent polarity reversals. This unique signal amplification not only significantly enhanced the sensitivity (a low detection limit of 4.3 pg/mL) but also remarkably extended the linear range (5 pg/mL to 10 μg/mL) across 6.5 orders of magnitude. Such performance proved to be highly suitable for the direct and accurate quantification of cTnI in serum samples from AMI patients without the need for dilution. As a result, the proposed method enabled a clear differentiation between positive and negative clinical samples, thereby substantially expanding the application potential of analytical chemistry in clinical diagnosis.

Analytical ChemistryVol. 97(39)
Nanjing Tech University (CN), Nanjing Normal University (CN), Institute of Molecular Functional Materials (CN), State Key Laboratory of Analytical Chemistry for Life Science (CN), Nanjing University (CN)
Openalex Percentile: Top 77%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.