Microsecond Electron Drift Observed by Band-Pass Kelvin Probe Force Microscopy

Carrier drift in materials critically influences the performance of devices, such as transistors, solar cells, and lithium-ion batteries. While many advanced Kelvin Probe Force Microscopy (KPFM) techniques have been developed for characterizing ionic drift, visually observing electron drift is challenging. This difficulty arises because electrons drift much faster than ions but are more susceptible to instrumental noise, necessitating methods with higher spatiotemporal resolution and improved signal-to-noise ratios. Here, we introduce a band-pass Kelvin Probe Force Microscopy (BP-KPFM) method that employs the frequency spectrum analysis of probe deflection along with a custom band-pass algorithm. This technique achieves precise quantitative measurements of potential with nanometer spatial and microsecond temporal resolution, capturing the dynamic and inhomogeneous process of electron drift at an average velocity of 1.4 ± 0.1 nm/μs. The BP-KPFM method can be applied broadly to study fast charge transport processes in advanced information and energy devices.

Authors

Institutions

Publication Details

Journal
ACS Nano
Published
2025-09-22
DOI
https://doi.org/10.1021/acsnano.5c11592
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microsecond Electron Drift Observed by Band-Pass Kelvin Probe Force Microscopy

Boyuan Huang, Wenjie Ming, Jiangyu Li, Youna Huang et al.
ACS Nano
Force Microscopy Techniques and Applications
article

Microsecond Electron Drift Observed by Band-Pass Kelvin Probe Force Microscopy

Boyuan Huang, Wenjie Ming, Jiangyu Li, Youna Huang, Fang Wang, Chunlin Song, Fengyuan Zhang
article en

Abstract

Carrier drift in materials critically influences the performance of devices, such as transistors, solar cells, and lithium-ion batteries. While many advanced Kelvin Probe Force Microscopy (KPFM) techniques have been developed for characterizing ionic drift, visually observing electron drift is challenging. This difficulty arises because electrons drift much faster than ions but are more susceptible to instrumental noise, necessitating methods with higher spatiotemporal resolution and improved signal-to-noise ratios. Here, we introduce a band-pass Kelvin Probe Force Microscopy (BP-KPFM) method that employs the frequency spectrum analysis of probe deflection along with a custom band-pass algorithm. This technique achieves precise quantitative measurements of potential with nanometer spatial and microsecond temporal resolution, capturing the dynamic and inhomogeneous process of electron drift at an average velocity of 1.4 ± 0.1 nm/μs. The BP-KPFM method can be applied broadly to study fast charge transport processes in advanced information and energy devices.

ACS NanoVol. 19(39)
Southern University of Science and Technology (CN), China University of Geosciences (CN)
Openalex Percentile: Top 79%
Force Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.