In vivo monitoring in radiological or nuclear emergencies: a program for intercomparison of detection efficiency in NaI(Tl) portable detectors

In vivo internal monitoring is a laboratory technique used to assess and quantify the incorporation of radionuclides in the human body. Demand for such services may increase significantly in a radiological or nuclear emergency. In addition to dedicated laboratories, researchers have proposed the calibration of portable gamma radiation detectors to carry out a rapid screening of exposed individuals and assess internal dosimetry. Several international intercomparison exercises have been conducted to evaluate the performance of detectors specifically designed for internal monitoring, including, more recently, NaI(Tl) portable detectors. However, these experimental intercomparison exercises have included the transport of radioactive sources between participating institutions. The aim of this study is to propose a simple methodology for determining a reference value for the NaI(Tl) detector efficiency at 662 keV (137Cs), supporting future exercise efforts. This work employed NaI(Tl) scintillator detectors and a torso phantom. It was possible to determine an optimized measurement geometry through simulation using the MCNPX mathematical code, especially regarding the distances, and to estimate efficiency values with defined acceptance intervals for the proposed intercomparison exercise. However, additional experiments are needed to define these intervals more precisely. Complementarily, the minimum detectable effective doses were approximately 60 µSv and 38 µSv for the NaI(Tl) 2’’×2’’ and 3’’×1.5’’ detectors, respectively.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2025-09-19
DOI
https://doi.org/10.15392/2319-0612.2025.2895
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo monitoring in radiological or nuclear emergencies: a program for intercomparison of detection efficiency in NaI(Tl) portable detectors

José Ubiratan Delgado, Alexandre Barbosa Soares, Alfredo Lopes Ferreira Filho, Gabriel Marques
Brazilian Journal of Radiation Sciences
Radiation Detection and Scintillator Technologies
article

In vivo monitoring in radiological or nuclear emergencies: a program for intercomparison of detection efficiency in NaI(Tl) portable detectors

José Ubiratan Delgado, Alexandre Barbosa Soares, Alfredo Lopes Ferreira Filho, Gabriel Marques
article en

Abstract

In vivo internal monitoring is a laboratory technique used to assess and quantify the incorporation of radionuclides in the human body. Demand for such services may increase significantly in a radiological or nuclear emergency. In addition to dedicated laboratories, researchers have proposed the calibration of portable gamma radiation detectors to carry out a rapid screening of exposed individuals and assess internal dosimetry. Several international intercomparison exercises have been conducted to evaluate the performance of detectors specifically designed for internal monitoring, including, more recently, NaI(Tl) portable detectors. However, these experimental intercomparison exercises have included the transport of radioactive sources between participating institutions. The aim of this study is to propose a simple methodology for determining a reference value for the NaI(Tl) detector efficiency at 662 keV (137Cs), supporting future exercise efforts. This work employed NaI(Tl) scintillator detectors and a torso phantom. It was possible to determine an optimized measurement geometry through simulation using the MCNPX mathematical code, especially regarding the distances, and to estimate efficiency values with defined acceptance intervals for the proposed intercomparison exercise. However, additional experiments are needed to define these intervals more precisely. Complementarily, the minimum detectable effective doses were approximately 60 µSv and 38 µSv for the NaI(Tl) 2’’×2’’ and 3’’×1.5’’ detectors, respectively.

Brazilian Journal of Radiation SciencesVol. 13(3)
United States Department of the Army (US), United States Army (US), Instituto de Radioproteção e Dosimetria (BR), Radiation Protection Institute (UA), PLA Army Engineering University (CN)
Openalex Percentile: Top 67%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.