Determination of the NETD Parameter Value of the Imaging System with a Single MWIR Detector for CO2 Detection

This research presents the experimental assessment of the NETD parameter for an infrared system developed for gas detection using the single-pixel imaging technique. Gas imaging systems often uses the narrow-band filtering for contrast enhancement which significantly reduces the incoming radiation energy and deteriorates the signal-to-noise characteristic. The developed system was tested for CO2 detection in MWIR wavelength band. The presented results confirmed experimentally the higher value of the NETD parameter for the system equipped with the interference filter. The NETD parameter was evaluated using a simple testing stand with the black body for selecting the proper background temperature. The obtained results confirm the importance of the background temperature in the detection process, the value of which is important in determining the sensitivity and noise level of the system, the attenuation of the radiation of optical elements and the spectral characteristics of the detected gas.

Authors

Publication Details

Journal
Pomiary Automatyka Robotyka
Published
2025-09-18
DOI
https://doi.org/10.14313/par_257/59
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the NETD Parameter Value of the Imaging System with a Single MWIR Detector for CO2 Detection

R. Olbrycht, B. Więcek, Sebastian Urbaś
Pomiary Automatyka Robotyka
Atmospheric and Environmental Gas Dynamics
article

Determination of the NETD Parameter Value of the Imaging System with a Single MWIR Detector for CO2 Detection

R. Olbrycht, B. Więcek, Sebastian Urbaś
article en

Abstract

This research presents the experimental assessment of the NETD parameter for an infrared system developed for gas detection using the single-pixel imaging technique. Gas imaging systems often uses the narrow-band filtering for contrast enhancement which significantly reduces the incoming radiation energy and deteriorates the signal-to-noise characteristic. The developed system was tested for CO2 detection in MWIR wavelength band. The presented results confirmed experimentally the higher value of the NETD parameter for the system equipped with the interference filter. The NETD parameter was evaluated using a simple testing stand with the black body for selecting the proper background temperature. The obtained results confirm the importance of the background temperature in the detection process, the value of which is important in determining the sensitivity and noise level of the system, the attenuation of the radiation of optical elements and the spectral characteristics of the detected gas.

Pomiary Automatyka RobotykaVol. 29(3)
Openalex Percentile: Top 76%
Atmospheric and Environmental Gas Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.