Impact of sintering time on corrosion rate and relative density of titanium, titanium-aluminum alloy, and titanium-based composites for bio-applications

The corrosion of implanted metals in the human body results in degradation and the release of harmful ions. Titanium and its alloys are used in biomedical applications due to their corrosion resistance and biocompatibility. This study examines how the amount of time spent sintering affects the density and corrosion resistance of Ti, Ti-6% Al, and Ti-6 % Al-2% HA (hydroxyapatite). Al was incorporated into Ti to reduce its density and enhance corrosion resistance. In contrast, HA was added at 2%, which aims to improve bioactivity and facilitate better integration with bone tissue. The samples were fabricated through powder metallurgy by mixing for 4 hours, and the compaction was 550 MPa. We sintered all samples at 1,300 °C, with varying sintering times of 60, 90, and 120 minutes. The results indicated that samples sintered for 120 minutes exhibited the highest relative densities: 91.55% for Ti, 92.89% for Ti-6%Al, and 93.24% for Ti-6%Al-2%HA. These samples demonstrated the lowest corrosion rates, with 0.2075 mpy for Ti, 0.01199 mpy for Ti-6%Al, and 0.003129 mpy for Ti-6%Al-2%HA. X-ray diffraction analysis of the Ti-6%Al-2%HA sample revealed patterns that corresponded to the titanium alloy and its byproducts, which included Ti, CaTi₄P₆O₂₄, TiP₂O₇, TiO₂, and CaTiO₃. Atomic absorption spectroscopy analysis found that only a small amount of titanium ions (0.912 ppm) was released, and no aluminum ions were detected over 14 days. Additionally, the MTT assay demonstrated 85.3% cell viability. These findings suggest that Ti-6%Al-2%HA alloys have potential applications in biomedical implants due to their improved corrosion resistance and biocompatibility.            

Authors

Institutions

Publication Details

Journal
Engineering and Technology Journal
Published
2025-09-21
DOI
https://doi.org/10.30684/etj.2025.156810.1886
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of sintering time on corrosion rate and relative density of titanium, titanium-aluminum alloy, and titanium-based composites for bio-applications

Niveen Jamal Abdulkader, Layth Al-Gebory, Mostafa Hadi
Engineering and Technology Journal
Titanium Alloys Microstructure and Properties
article

Impact of sintering time on corrosion rate and relative density of titanium, titanium-aluminum alloy, and titanium-based composites for bio-applications

Niveen Jamal Abdulkader, Layth Al-Gebory, Mostafa Hadi
article en

Abstract

The corrosion of implanted metals in the human body results in degradation and the release of harmful ions. Titanium and its alloys are used in biomedical applications due to their corrosion resistance and biocompatibility. This study examines how the amount of time spent sintering affects the density and corrosion resistance of Ti, Ti-6% Al, and Ti-6 % Al-2% HA (hydroxyapatite). Al was incorporated into Ti to reduce its density and enhance corrosion resistance. In contrast, HA was added at 2%, which aims to improve bioactivity and facilitate better integration with bone tissue. The samples were fabricated through powder metallurgy by mixing for 4 hours, and the compaction was 550 MPa. We sintered all samples at 1,300 °C, with varying sintering times of 60, 90, and 120 minutes. The results indicated that samples sintered for 120 minutes exhibited the highest relative densities: 91.55% for Ti, 92.89% for Ti-6%Al, and 93.24% for Ti-6%Al-2%HA. These samples demonstrated the lowest corrosion rates, with 0.2075 mpy for Ti, 0.01199 mpy for Ti-6%Al, and 0.003129 mpy for Ti-6%Al-2%HA. X-ray diffraction analysis of the Ti-6%Al-2%HA sample revealed patterns that corresponded to the titanium alloy and its byproducts, which included Ti, CaTi₄P₆O₂₄, TiP₂O₇, TiO₂, and CaTiO₃. Atomic absorption spectroscopy analysis found that only a small amount of titanium ions (0.912 ppm) was released, and no aluminum ions were detected over 14 days. Additionally, the MTT assay demonstrated 85.3% cell viability. These findings suggest that Ti-6%Al-2%HA alloys have potential applications in biomedical implants due to their improved corrosion resistance and biocompatibility.            

Engineering and Technology JournalVol. 0(0)
University of Technology - Iraq (IQ), Iraqi University (IQ)
Openalex Percentile: Top 80%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.