Exploring Caffeine Extraction Using Hydrophobic Deep Eutectic Solvents: Experimental and Theoretical Approaches

Hydrophobic deep eutectic solvents (HDESs) are emerging as sustainable, biodegradable, and nontoxic alternatives to traditional organic solvents in liquid-liquid extraction processes. This study investigates the use of HDESs, specifically eutectic mixtures of dl-menthol combined with acetic or hexanoic acids, for extracting caffeine from coffee beans (CB), coffee skin (CS), and guaraná drink (GD). Solvent screening using COSMO-RS modeling was performed to identify effective HDES systems. Caffeine detection employed UV/vis spectrophotometry at 274 nm (dl-menthol/acetic acid system) and 284 nm (dl-menthol/hexanoic acid system), with application of Gaussian fitting to minimize spectral interferences. The optimal extraction conditions were determined to be 65 °C and a 1:1 initial solution to solvent (L/L) ratio. Under these conditions, the dl-menthol/acetic acid solvent extracted 0.765 ± 0.007 mg of caffeine per 100 mg of coffee beans, outperforming the dl-menthol/hexanoic acid solvent, which extracted 0.610 ± 0.010 mg. Comparable results were observed for the other matrices, with 0.66 ± 0.01 mg caffeine per 400 mg of coffee skin and 0.57 ± 0.01 mg per 10 mL of guaraná drink. The method presented high precision, with a standard deviation of ±0.0826 mg L<sup>-1</sup> for five measurements of a 15 mg L<sup>-1</sup> caffeine solution, and detection and quantification limits of 0.674 and 2.04 mg L<sup>-1</sup>, respectively. The sustainability of the method was evaluated using the AGREE (Analytical GREEnness) metric, obtaining a high greenness score of 0.83, exceeding the values for traditional solvents such as dichloromethane and chloroform. These findings demonstrated the potential of HDESs as greener, safer, and more efficient alternatives for caffeine extraction, aligning with green chemistry principles and supported by both experimental and theoretical evaluations.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-09-20
DOI
https://doi.org/10.1021/acsomega.5c05673
Citations
1
Primary Topic
Ionic liquids properties and applications
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Caffeine Extraction Using Hydrophobic Deep Eutectic Solvents: Experimental and Theoretical Approaches

Rafaela Silva Lamarca, Clarice D.B. Amaral, Khatereh Ali Pishro, Laércio Santos Silva et al.
1 citations
ACS Omega
Ionic liquids properties and applications
0.39
article

Exploring Caffeine Extraction Using Hydrophobic Deep Eutectic Solvents: Experimental and Theoretical Approaches

Rafaela Silva Lamarca, Clarice D.B. Amaral, Khatereh Ali Pishro, Laércio Santos Silva, Mário H. Gonzalez
article en
1 citations

Abstract

Hydrophobic deep eutectic solvents (HDESs) are emerging as sustainable, biodegradable, and nontoxic alternatives to traditional organic solvents in liquid-liquid extraction processes. This study investigates the use of HDESs, specifically eutectic mixtures of dl-menthol combined with acetic or hexanoic acids, for extracting caffeine from coffee beans (CB), coffee skin (CS), and guaraná drink (GD). Solvent screening using COSMO-RS modeling was performed to identify effective HDES systems. Caffeine detection employed UV/vis spectrophotometry at 274 nm (dl-menthol/acetic acid system) and 284 nm (dl-menthol/hexanoic acid system), with application of Gaussian fitting to minimize spectral interferences. The optimal extraction conditions were determined to be 65 °C and a 1:1 initial solution to solvent (L/L) ratio. Under these conditions, the dl-menthol/acetic acid solvent extracted 0.765 ± 0.007 mg of caffeine per 100 mg of coffee beans, outperforming the dl-menthol/hexanoic acid solvent, which extracted 0.610 ± 0.010 mg. Comparable results were observed for the other matrices, with 0.66 ± 0.01 mg caffeine per 400 mg of coffee skin and 0.57 ± 0.01 mg per 10 mL of guaraná drink. The method presented high precision, with a standard deviation of ±0.0826 mg L<sup>-1</sup> for five measurements of a 15 mg L<sup>-1</sup> caffeine solution, and detection and quantification limits of 0.674 and 2.04 mg L<sup>-1</sup>, respectively. The sustainability of the method was evaluated using the AGREE (Analytical GREEnness) metric, obtaining a high greenness score of 0.83, exceeding the values for traditional solvents such as dichloromethane and chloroform. These findings demonstrated the potential of HDESs as greener, safer, and more efficient alternatives for caffeine extraction, aligning with green chemistry principles and supported by both experimental and theoretical evaluations.

ACS OmegaVol. 10(38)
Universidade Federal do Paraná (BR), Universidade Estadual Paulista (Unesp) (BR)
Openalex Percentile: Top 39%
Ionic liquids properties and applications
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.