Crack Propagation in Tooth Root: A Comparison Between Pulsator Test and Running Gears

ABSTRACT Tooth root fatigue fracture is a critical gear failure mode in which the tooth root breaks because of the repetition of bending load. The most widely adopted procedure for evaluating root strength is through pulsator testing. However, this test method does not present gears in meshing conditions. When focusing on the limited‐life region of the SN curve, certain differences are observed between pulsator and running gear tests: A gear under meshing conditions presents a lifetime comparable, if not even higher, than that within pulsator testing. This study investigates the role of crack propagation in the tooth root and how it could explain this difference.

Authors

Institutions

Publication Details

Journal
Fatigue & Fracture of Engineering Materials & Structures
Published
2025-09-19
DOI
https://doi.org/10.1111/ffe.70094
Citations
2
Primary Topic
Metal Alloys Wear and Properties
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Crack Propagation in Tooth Root: A Comparison Between Pulsator Test and Running Gears

Michael Geitner, Luca Bonaiti, Thomas Tobie, Carlo Gorla et al.
2 citations
Fatigue & Fracture of Engineering Materials & Structures
Metal Alloys Wear and Properties
1.04
article

Crack Propagation in Tooth Root: A Comparison Between Pulsator Test and Running Gears

Michael Geitner, Luca Bonaiti, Thomas Tobie, Carlo Gorla, Karsten Stahl, Lorenzo Valsecchi
article en
2 citations

Abstract

ABSTRACT Tooth root fatigue fracture is a critical gear failure mode in which the tooth root breaks because of the repetition of bending load. The most widely adopted procedure for evaluating root strength is through pulsator testing. However, this test method does not present gears in meshing conditions. When focusing on the limited‐life region of the SN curve, certain differences are observed between pulsator and running gear tests: A gear under meshing conditions presents a lifetime comparable, if not even higher, than that within pulsator testing. This study investigates the role of crack propagation in the tooth root and how it could explain this difference.

Fatigue & Fracture of Engineering Materials & StructuresVol. 48(12)
Technical University of Munich (DE), Politecnico di Milano (IT)
Openalex Percentile: Top 22%
Metal Alloys Wear and Properties
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.