Measurement variability in residential PM2.5: an evaluation of a low-cost sensor in the Netherlands

Abstract Accurate residential air quality assessment is crucial for studying health risks, evaluating local mitigation measures, and empowering citizens. Low-cost-sensors (LCS) have gained popularity for enhancing monitoring coverage and providing individuals with air quality measurement tools. This study examines the added value of a low-cost sensor in estimating residential fine particulate matter (PM 2.5 ) concentrations in the Netherlands. We employed a real-time Sensirion SPS30 dust sensor to monitor residential PM 2.5 concentrations. 73 sensors were deployed outdoors at participants’ residences with an average measurement time of 131 days. Data from LCS were compared with that of regulatory stations, using hourly and daily averages for comparison. Spatial variability of sensor measurements was assessed, and determinants were explored that explain potential differences between PM 2.5 concentrations from regulatory stations and LCS measurements. After data cleaning, 95.7% of measurements were retained. Meteorological factors did not impact sensor performance. The mean Pearson temporal correlation between the LCS and regulatory network was 0.75 for hourly and 0.88 for daily PM 2.5 averages. The average difference ranged from − 0.17 to 0.63 µg/m 3 , and the average absolute difference ranged from 2.42 to 4.50 µg/m 3 . Spatial variability of LCS-based average concentrations at similar locations was larger than that of regulatory stations. LCS measuring direction, traffic intensity, humidity, LCS readings, and distance to nearest background station had a significant effect on the difference between sensor and regulatory station concentrations. This study demonstrates that PM 2.5 can be accurately measured over extended periods using LCS, offering a dynamic, high-quality perspective on air quality, recording variations that regulatory stations and predictive air quality models may overlook.

Authors

Institutions

Publication Details

Journal
Air Quality Atmosphere & Health
Published
2025-09-20
DOI
https://doi.org/10.1007/s11869-025-01833-1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement variability in residential PM2.5: an evaluation of a low-cost sensor in the Netherlands

George S. Downward, Anke H. Maitland‐van der Zee, Lizan D. Bloemsma, Laura Houweling et al.
Air Quality Atmosphere & Health
Air Quality Monitoring and Forecasting
article

Measurement variability in residential PM2.5: an evaluation of a low-cost sensor in the Netherlands

George S. Downward, Anke H. Maitland‐van der Zee, Lizan D. Bloemsma, Laura Houweling, Judith C.S. Holtjer, Gerard Hoek
article en

Abstract

Abstract Accurate residential air quality assessment is crucial for studying health risks, evaluating local mitigation measures, and empowering citizens. Low-cost-sensors (LCS) have gained popularity for enhancing monitoring coverage and providing individuals with air quality measurement tools. This study examines the added value of a low-cost sensor in estimating residential fine particulate matter (PM 2.5 ) concentrations in the Netherlands. We employed a real-time Sensirion SPS30 dust sensor to monitor residential PM 2.5 concentrations. 73 sensors were deployed outdoors at participants’ residences with an average measurement time of 131 days. Data from LCS were compared with that of regulatory stations, using hourly and daily averages for comparison. Spatial variability of sensor measurements was assessed, and determinants were explored that explain potential differences between PM 2.5 concentrations from regulatory stations and LCS measurements. After data cleaning, 95.7% of measurements were retained. Meteorological factors did not impact sensor performance. The mean Pearson temporal correlation between the LCS and regulatory network was 0.75 for hourly and 0.88 for daily PM 2.5 averages. The average difference ranged from − 0.17 to 0.63 µg/m 3 , and the average absolute difference ranged from 2.42 to 4.50 µg/m 3 . Spatial variability of LCS-based average concentrations at similar locations was larger than that of regulatory stations. LCS measuring direction, traffic intensity, humidity, LCS readings, and distance to nearest background station had a significant effect on the difference between sensor and regulatory station concentrations. This study demonstrates that PM 2.5 can be accurately measured over extended periods using LCS, offering a dynamic, high-quality perspective on air quality, recording variations that regulatory stations and predictive air quality models may overlook.

Air Quality Atmosphere & HealthVol. 18(10)
University Medical Center Groningen (NL), University of Groningen (NL), Utrecht University (NL), University Medical Center Utrecht (NL), Amsterdam Neuroscience (NL), GGD Amsterdam (NL), Amsterdam University of Applied Sciences (NL), University of Amsterdam (NL)
Danone, Danone Nutricia Research, Amsterdam University Medical Centers, Universiteit Leiden, Universiteit Utrecht, Universiteit Maastricht, Universitair Medisch Centrum Utrecht, Maastricht Universitair Medisch Centrum, Leids Universitair Medisch Centrum
Openalex Percentile: Top 77%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.