Accuracy of Navigated High-Speed Drill-Assisted Cervical and Upper Thoracic Pedicle Screw Placement—A Single Center Experience with 1112 Pedicle Screws

<b>Background/Objectives</b>: While biomechanically superior, cervical pedicle screw placement is technically challenging, and therefore typically performed only in centers with the aid of navigation. The purpose of this study was to analyze the accuracy and safety of navigated cervical pedicle screw (CPS) placement using intraoperative imaging with a workflow using a navigated high-speed drill in a large single-center cohort. <b>Methods</b>: We conducted a retrospective analysis of 205 patients undergoing posterior cervical or cervicothoracic instrumentation between January 2018 and June 2024. Accuracy was assessed using the Gertzbein-Robbins classification, with grades 0 and 1 considered satisfactory. Surgical workflow, intraoperative imaging, and complications were analyzed. <b>Results</b>: A total of 1112 pedicle screws, including 888 cervical and 224 upper thoracic screws, were evaluated. 801 were grade 0 (72.0%), 250 grade 1 (22.5%), 56 grade 2 (5.0%), and 5 grade 3 (0.4%). Cervical screws achieved satisfactory placement grades 0 and 1 in 93.1%, and upper thoracic screws in 100% (92.0% grade 0, 8.0% grade 1). Grade 3 breaches occurred in C2, C3, C5, C6, and C7, with one case each. There were no cases of implant-related neurovascular injuries. <b>Conclusions</b>: This study demonstrates high screw accuracy with a low observed complication rate. No revision surgeries were required due to screw malposition, but 7 cases of screw loosening occurred. However, the retrospective design and reliance on intraoperative imaging limit the generalizability of the findings.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-19
DOI
https://doi.org/10.3390/jcm14186597
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Navigated High-Speed Drill-Assisted Cervical and Upper Thoracic Pedicle Screw Placement—A Single Center Experience with 1112 Pedicle Screws

Philip Rauch, Stephan Heisinger, Andreas J Gruber, Wolfgang Senker et al.
Journal of Clinical Medicine
Spinal Fractures and Fixation Techniques
article

Accuracy of Navigated High-Speed Drill-Assisted Cervical and Upper Thoracic Pedicle Screw Placement—A Single Center Experience with 1112 Pedicle Screws

Philip Rauch, Stephan Heisinger, Andreas J Gruber, Wolfgang Senker, Stefan Aspalter, Nico Stroh-Holly, Katja Höllmüller, Armin Davachi
article en

Abstract

<b>Background/Objectives</b>: While biomechanically superior, cervical pedicle screw placement is technically challenging, and therefore typically performed only in centers with the aid of navigation. The purpose of this study was to analyze the accuracy and safety of navigated cervical pedicle screw (CPS) placement using intraoperative imaging with a workflow using a navigated high-speed drill in a large single-center cohort. <b>Methods</b>: We conducted a retrospective analysis of 205 patients undergoing posterior cervical or cervicothoracic instrumentation between January 2018 and June 2024. Accuracy was assessed using the Gertzbein-Robbins classification, with grades 0 and 1 considered satisfactory. Surgical workflow, intraoperative imaging, and complications were analyzed. <b>Results</b>: A total of 1112 pedicle screws, including 888 cervical and 224 upper thoracic screws, were evaluated. 801 were grade 0 (72.0%), 250 grade 1 (22.5%), 56 grade 2 (5.0%), and 5 grade 3 (0.4%). Cervical screws achieved satisfactory placement grades 0 and 1 in 93.1%, and upper thoracic screws in 100% (92.0% grade 0, 8.0% grade 1). Grade 3 breaches occurred in C2, C3, C5, C6, and C7, with one case each. There were no cases of implant-related neurovascular injuries. <b>Conclusions</b>: This study demonstrates high screw accuracy with a low observed complication rate. No revision surgeries were required due to screw malposition, but 7 cases of screw loosening occurred. However, the retrospective design and reliance on intraoperative imaging limit the generalizability of the findings.

Journal of Clinical MedicineVol. 14(18)
Kepler Universitätsklinikum (AT), Medical University of Vienna (AT)
Openalex Percentile: Top 59%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.