At-Home Urea Breath Testing Demonstrates Increased Patient Uptake, High Satisfaction Rates, and Reduction in Carbon Emission Due to Eliminated Hospital Attendances, While Maintaining Diagnostic Accuracy for H. pylori

<b>Background/Objectives</b>: Healthcare accounts for approximately 4.4% of global carbon emissions. Gastroenterology is a particularly heavy producer, with professional organisations outlining targets to move towards carbon neutrality. Missed hospital appointments, associated with poor medical outcomes, also represent physical and economic waste to the sector. COVID-19 expedited the shift toward virtual clinics, but tele-diagnostics have not expanded similarly. We aimed to assess the feasibility of a virtual C13 urea breath test clinic for <i>H. pylori</i> in Ireland. <b>Methods</b>: C13 urea breath test kits were provided to patients in the community, who were subsequently invited to book an online video appointment with a GI lab technician to assist them in performing the test at home. Completed tests were returned to the hospital via local GP, by post, or a specified hospital drop-off point, and analysed using our standard protocol. <b>Results</b>: 423 virtual appointments were reviewed. 135 (32%) were male, and the mean age was 42 years. The test positivity rate was 22%, similar to a matched in-person testing cohort (21%). In all, there were no non-attenders, and two cancellations. Virtual patients were more likely to attend their appointments (OR = 153.9, <i>p</i> = 0.0004) than in-person patients. Virtual UBT appointments saved 9943.5 Km of road journeys, equivalent to 254 person-hours of travel time and 1.24 metric tonnes of CO<sub>2</sub>. Additionally, 300 (71%) patients returned a feedback questionnaire, of which 276 (92%) rated the overall home breath test experience as 'good' or 'excellent'. <b>Conclusions</b>: Home testing for <i>H. pylori</i> is effective, acceptable, and reduces both reliance on invasive procedures such as endoscopy and carbon emissions.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-09-19
DOI
https://doi.org/10.3390/jcm14186598
Citations
1
Primary Topic
Climate Change and Health Impacts
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

At-Home Urea Breath Testing Demonstrates Increased Patient Uptake, High Satisfaction Rates, and Reduction in Carbon Emission Due to Eliminated Hospital Attendances, While Maintaining Diagnostic Accuracy for H. pylori

Conor Costigan, Deirdre A. McNamara, Emmanuel Omallao, Edric Leung et al.
1 citations
Journal of Clinical Medicine
Climate Change and Health Impacts
1.20
article

At-Home Urea Breath Testing Demonstrates Increased Patient Uptake, High Satisfaction Rates, and Reduction in Carbon Emission Due to Eliminated Hospital Attendances, While Maintaining Diagnostic Accuracy for H. pylori

Conor Costigan, Deirdre A. McNamara, Emmanuel Omallao, Edric Leung, Sandeep Sihag
article en
1 citations

Abstract

<b>Background/Objectives</b>: Healthcare accounts for approximately 4.4% of global carbon emissions. Gastroenterology is a particularly heavy producer, with professional organisations outlining targets to move towards carbon neutrality. Missed hospital appointments, associated with poor medical outcomes, also represent physical and economic waste to the sector. COVID-19 expedited the shift toward virtual clinics, but tele-diagnostics have not expanded similarly. We aimed to assess the feasibility of a virtual C13 urea breath test clinic for <i>H. pylori</i> in Ireland. <b>Methods</b>: C13 urea breath test kits were provided to patients in the community, who were subsequently invited to book an online video appointment with a GI lab technician to assist them in performing the test at home. Completed tests were returned to the hospital via local GP, by post, or a specified hospital drop-off point, and analysed using our standard protocol. <b>Results</b>: 423 virtual appointments were reviewed. 135 (32%) were male, and the mean age was 42 years. The test positivity rate was 22%, similar to a matched in-person testing cohort (21%). In all, there were no non-attenders, and two cancellations. Virtual patients were more likely to attend their appointments (OR = 153.9, <i>p</i> = 0.0004) than in-person patients. Virtual UBT appointments saved 9943.5 Km of road journeys, equivalent to 254 person-hours of travel time and 1.24 metric tonnes of CO<sub>2</sub>. Additionally, 300 (71%) patients returned a feedback questionnaire, of which 276 (92%) rated the overall home breath test experience as 'good' or 'excellent'. <b>Conclusions</b>: Home testing for <i>H. pylori</i> is effective, acceptable, and reduces both reliance on invasive procedures such as endoscopy and carbon emissions.

Journal of Clinical MedicineVol. 14(18)
Tallaght University Hospital (IE)
Openalex Percentile: Top 18%
Climate Change and Health Impacts
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.