Long-term Outcomes of Poly-4-Hydroxybutyrate (P4HB) in Aesthetic Breast Surgery: An International Experience

Abstract Background Poly-4-hydroxybutyrate (P4HB), a naturally occurring component of human connective tissue, serves as a biomedically produced thermoplastic polyester scaffold that has been used in many surgical subspecialties. The utilization of P4HB in cosmetic and reconstructive breast surgery has been popularized internationally for the past 12 years. Objectives The purpose of this study was to assess and report long-term international outcomes of P4HB use in aesthetic breast surgery. Methods A standardized retrospective outcome review was completed from the records of 5 international surgeons, each with significant expertise in using P4HB. Results A total of 621 patients were included in the review. Average follow-up was 1.33 years (range, 1-9.3 years). Most patients had P4HB placed during primary breast surgery (n = 460; 74%); primary procedures included augmentation-mastopexy (n = 253), mastopexy (n = 125), and breast reduction (n = 71). A subset (n = 161; 26%) of patients had P4HB placed during breast revisions, including revision augmentation-mastopexy (n = 81), revision augmentation (n = 73), and mastopexy with implant removal (n = 7). The main indications for revision included recurrent ptosis (n = 166), implant malposition (n = 64), and capsular contracture (n = 61). An overall complication rate of 3.7% (n = 23) was observed, the most common being delayed wound healing (n = 7) and hypertrophic scarring (n = 5). Of the overall complications, device-related complications associated with P4HB were observed only in 5 patients (0.8%), while non–device-related complications were seen in 18 patients (2.9%). Conclusions This study suggests there is a defined role for the use of P4HB in both primary and revision aesthetic breast surgery; its use does not appear to increase the inherent complication risk of cosmetic breast surgery. Level of Evidence: 4 (Therapeutic)

Authors

Institutions

Publication Details

Journal
Aesthetic Surgery Journal
Published
2025-08-27
DOI
https://doi.org/10.1093/asj/sjaf173
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-term Outcomes of Poly-4-Hydroxybutyrate (P4HB) in Aesthetic Breast Surgery: An International Experience

Christoph Andree, Barbara Cagli, Shikhar Tomur, S Pompei et al.
Aesthetic Surgery Journal
Breast Implant and Reconstruction
article

Long-term Outcomes of Poly-4-Hydroxybutyrate (P4HB) in Aesthetic Breast Surgery: An International Experience

Christoph Andree, Barbara Cagli, Shikhar Tomur, S Pompei, Giovanni Bistoni, Adam D. Glener, William P. Adams
article en

Abstract

Abstract Background Poly-4-hydroxybutyrate (P4HB), a naturally occurring component of human connective tissue, serves as a biomedically produced thermoplastic polyester scaffold that has been used in many surgical subspecialties. The utilization of P4HB in cosmetic and reconstructive breast surgery has been popularized internationally for the past 12 years. Objectives The purpose of this study was to assess and report long-term international outcomes of P4HB use in aesthetic breast surgery. Methods A standardized retrospective outcome review was completed from the records of 5 international surgeons, each with significant expertise in using P4HB. Results A total of 621 patients were included in the review. Average follow-up was 1.33 years (range, 1-9.3 years). Most patients had P4HB placed during primary breast surgery (n = 460; 74%); primary procedures included augmentation-mastopexy (n = 253), mastopexy (n = 125), and breast reduction (n = 71). A subset (n = 161; 26%) of patients had P4HB placed during breast revisions, including revision augmentation-mastopexy (n = 81), revision augmentation (n = 73), and mastopexy with implant removal (n = 7). The main indications for revision included recurrent ptosis (n = 166), implant malposition (n = 64), and capsular contracture (n = 61). An overall complication rate of 3.7% (n = 23) was observed, the most common being delayed wound healing (n = 7) and hypertrophic scarring (n = 5). Of the overall complications, device-related complications associated with P4HB were observed only in 5 patients (0.8%), while non–device-related complications were seen in 18 patients (2.9%). Conclusions This study suggests there is a defined role for the use of P4HB in both primary and revision aesthetic breast surgery; its use does not appear to increase the inherent complication risk of cosmetic breast surgery. Level of Evidence: 4 (Therapeutic)

Aesthetic Surgery JournalVol. 46(3)
University of North Carolina Wilmington (US), Università Campus Bio-Medico (IT), Düsseldorf University Hospital (DE), Sapienza University of Rome (IT), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 59%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.