Examination of unique volatile organic compound signatures in nasopharyngeal test swab viral transport media using an electronic nose

Rapid point of care tests for respiratory infections are associated with high rates of false negative results which can drive empiric, and potentially inappropriate, antibiotic use. Because infectious pathogens alter VOC composition, unique VOC signatures in biospecimens hold the potential to discriminate bacterial and viral infections from uninfected controls. One approach for rapid identification of respiratory pathogens is the electronic nose (e-nose), a sensor device that uses artificial intelligence to recognize disease-specific patterns in VOC profiles of gaseous mixtures. In this preclinical proof of concept study, we tested the validity of an e-nose to discriminate PCR-confirmed cases of infection with three viral pathogens (SARS-CoV-2, RSV, influenza A) from uninfected controls using nasopharyngeal test swab media. Using exploratory factor analysis, the e-nose discriminated both influenza A and SAR-CoV-2 from uninfected controls. To assess sensitivity and specificity, we applied factor analysis-based threshold values and obtained high levels of sensitivity (96.30%) and specificity (90.62%) for influenza A and more modest levels for SARS-CoV-2 (sensitivity=75%, specificity=68.57%). We did not apply threshold values to RSV samples because the e-nose sensors showed low discriminatory power for that pathogen. Our findings support proof of concept of the validity of the e-nose to discriminate common viral respiratory pathogens. Our use of binary thresholds for influenza A, which are easily adapted to point-of-care settings, yielded superior sensitivity results and comparable specificity results when compared to rapid tests. We recommend that future studies apply our analytic approach to samples of human breath to determine if these findings can be replicated or improved.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-09-19
DOI
https://doi.org/10.1371/journal.pone.0332399
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examination of unique volatile organic compound signatures in nasopharyngeal test swab viral transport media using an electronic nose

Ali Keshavarzian, Jessica Bishop‐Royse, Barbara Swanson, Alan Landay et al.
1 citations
PLoS ONE
Advanced Chemical Sensor Technologies
0.67
article

Examination of unique volatile organic compound signatures in nasopharyngeal test swab viral transport media using an electronic nose

Ali Keshavarzian, Jessica Bishop‐Royse, Barbara Swanson, Alan Landay, Maryan Arrieta, Min‐Jong Kang, Abhinav Bhushan, Wrenetha Julion, James N. Moy, Dylan Behun, R.A. Balk, Jhalak Mehta, Michael Bowlen
article en
1 citations

Abstract

Rapid point of care tests for respiratory infections are associated with high rates of false negative results which can drive empiric, and potentially inappropriate, antibiotic use. Because infectious pathogens alter VOC composition, unique VOC signatures in biospecimens hold the potential to discriminate bacterial and viral infections from uninfected controls. One approach for rapid identification of respiratory pathogens is the electronic nose (e-nose), a sensor device that uses artificial intelligence to recognize disease-specific patterns in VOC profiles of gaseous mixtures. In this preclinical proof of concept study, we tested the validity of an e-nose to discriminate PCR-confirmed cases of infection with three viral pathogens (SARS-CoV-2, RSV, influenza A) from uninfected controls using nasopharyngeal test swab media. Using exploratory factor analysis, the e-nose discriminated both influenza A and SAR-CoV-2 from uninfected controls. To assess sensitivity and specificity, we applied factor analysis-based threshold values and obtained high levels of sensitivity (96.30%) and specificity (90.62%) for influenza A and more modest levels for SARS-CoV-2 (sensitivity=75%, specificity=68.57%). We did not apply threshold values to RSV samples because the e-nose sensors showed low discriminatory power for that pathogen. Our findings support proof of concept of the validity of the e-nose to discriminate common viral respiratory pathogens. Our use of binary thresholds for influenza A, which are easily adapted to point-of-care settings, yielded superior sensitivity results and comparable specificity results when compared to rapid tests. We recommend that future studies apply our analytic approach to samples of human breath to determine if these findings can be replicated or improved.

PLoS ONEVol. 20(9)
Baylor University (US), Illinois Institute of Technology (US), Baylor College of Medicine (US), Rosalind Franklin University of Medicine and Science (US), Rush University (US), The University of Texas Medical Branch at Galveston (US)
Openalex Percentile: Top 27%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.