Light transport in the human spine for optical bone density assessment: Monte Carlo modeling and validation

Spinal disorders are an increasing global health concern, especially in aging populations. Conventional diagnostic methods rely on ionizing radiation, limiting their suitability for portable or frequent assessments. Near-infrared spectroscopy provides a promising non-invasive alternative for evaluating spinal properties, particularly bone mineral density (BMD). This study explores the feasibility of optical monitoring through Monte Carlo simulations based on the Visible Chinese Human dataset. Photon migration at 660, 808, and 980 nm was quantified and visualized, with 808 nm demonstrating the largest penetration depth of up to 3.5 cm in the spinal region. The optimal source-detector separation was identified as 3.4-3.8 cm. In vivo measurements in human subjects further validated the reliability of the simulation results. The pilot experiment revealed a significant correlation between detected signal and BMD, with lower BMD associated with relatively higher light intensity. These findings highlight the potential of optical techniques for spinal BMD assessment and support the development of portable monitoring systems.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-09-19
DOI
https://doi.org/10.1364/boe.574894
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Light transport in the human spine for optical bone density assessment: Monte Carlo modeling and validation

Faguang Wang, Ting Li, Hengjie Su, Chenxi Yang
Biomedical Optics Express
Optical Imaging and Spectroscopy Techniques
article

Light transport in the human spine for optical bone density assessment: Monte Carlo modeling and validation

Faguang Wang, Ting Li, Hengjie Su, Chenxi Yang
article en

Abstract

Spinal disorders are an increasing global health concern, especially in aging populations. Conventional diagnostic methods rely on ionizing radiation, limiting their suitability for portable or frequent assessments. Near-infrared spectroscopy provides a promising non-invasive alternative for evaluating spinal properties, particularly bone mineral density (BMD). This study explores the feasibility of optical monitoring through Monte Carlo simulations based on the Visible Chinese Human dataset. Photon migration at 660, 808, and 980 nm was quantified and visualized, with 808 nm demonstrating the largest penetration depth of up to 3.5 cm in the spinal region. The optimal source-detector separation was identified as 3.4-3.8 cm. In vivo measurements in human subjects further validated the reliability of the simulation results. The pilot experiment revealed a significant correlation between detected signal and BMD, with lower BMD associated with relatively higher light intensity. These findings highlight the potential of optical techniques for spinal BMD assessment and support the development of portable monitoring systems.

Biomedical Optics ExpressVol. 16(10)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
Openalex Percentile: Top 62%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Light transport in the human spine for optical bone density assessment: Monte Carlo modeling and validation — Faguang Wang, Ting Li, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS