Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm

Successful thoracic endovascular aortic repair for chronic type B aortic dissection with an enlarged false lumen depends on complete exclusion of the false lumen. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) creates a single lumen in the dissected thoracic and abdominal aorta by disrupting the intima. We report our experience in the treatment of 3 cases of chronic dissection using the STABILISE procedure at our hospital from December 2019 to May 2022. The STABILISE technique appears to be an effective procedure; however, further evaluation of risk factors for complications such as intraoperative aortic rupture is necessary.

Authors

Institutions

Publication Details

Journal
Annals of Vascular Diseases
Published
2025-01-01
DOI
https://doi.org/10.3400/avd.cr.25-00046
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm

Kanako Kobayashi, Takahiro Shoji, Naoki Fujimura, Kyosuke Hosokawa et al.
Annals of Vascular Diseases
Aortic Disease and Treatment Approaches
article

Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm

Kanako Kobayashi, Takahiro Shoji, Naoki Fujimura, Kyosuke Hosokawa, Yujiro Kawai, Ayaka Yu, Takahito Itoh, Hirohisa Harada
article en

Abstract

Successful thoracic endovascular aortic repair for chronic type B aortic dissection with an enlarged false lumen depends on complete exclusion of the false lumen. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) creates a single lumen in the dissected thoracic and abdominal aorta by disrupting the intima. We report our experience in the treatment of 3 cases of chronic dissection using the STABILISE procedure at our hospital from December 2019 to May 2022. The STABILISE technique appears to be an effective procedure; however, further evaluation of risk factors for complications such as intraoperative aortic rupture is necessary.

Annals of Vascular DiseasesVol. 18(1)
Saiseikai Central Hospital (JP)
Openalex Percentile: Top 63%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm — Kanako Kobayashi, Takahiro Shoji, et al. · Annals of Vascular Diseases (2025) | TGRS Research Map | TGRS