A novel rapid single-integrated immunoassay for plasma thrombomodulin: analytical performance and multi-center clinical validation

Thrombotic diseases have emerged as a significant public health issue, with timely detection, diagnosis, and treatment being closely associated with patient prognosis. Consequently, the identification of highly sensitive and specific biochemical markers for thrombotic diseases holds substantial clinical importance. In this study, we developed a rapid, single-integrated quantitative detection method for thrombomodulin (TM). This method integrates all reagent components onto a single, sophisticated card strip, enabling the completion of the assay in merely 20 minutes. Such efficiency enhances the potential for early screening of thrombosis within community and primary care medical institutions. The analytical performance results indicate that the limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were determined to be 0.5, 0.8, and 1.2 TU mL<sup>-1</sup>, respectively. The repeatability and precision of the method were found to be significantly below 10%, with a linear range extending from 1.2 to 200 TU mL<sup>-1</sup>. Accuracy evaluations revealed relative biases of -3.35% and 4.79% for the two reference materials tested. Furthermore, clinical trials conducted across two clinical research centers involved a total of 236 clinical plasma samples. The results of the clinical analysis demonstrated excellent consistency with the reference reagent (Sysmex). The receiver operating characteristic (ROC) curve and significance analysis indicated that this method possesses commendable specificity and sensitivity. In summary, the single-integrated immunoassay method developed in this study represents a rapid, convenient, accurate, and sensitive detection approach. It is particularly well-suited for the early screening and diagnosis of thrombotic diseases in community and primary healthcare institutions.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay01241d
Citations
1
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel rapid single-integrated immunoassay for plasma thrombomodulin: analytical performance and multi-center clinical validation

Yankun Yang, Shuaipeng Li, Jianqi Nie, Chao Guo et al.
1 citations
Analytical Methods
Clinical Laboratory Practices and Quality Control
1.16
article

A novel rapid single-integrated immunoassay for plasma thrombomodulin: analytical performance and multi-center clinical validation

Yankun Yang, Shuaipeng Li, Jianqi Nie, Chao Guo, Ziyan Xie, Zhonghu Bai, Yang Sun, Meng Liu, Qi Miao
article en
1 citations

Abstract

Thrombotic diseases have emerged as a significant public health issue, with timely detection, diagnosis, and treatment being closely associated with patient prognosis. Consequently, the identification of highly sensitive and specific biochemical markers for thrombotic diseases holds substantial clinical importance. In this study, we developed a rapid, single-integrated quantitative detection method for thrombomodulin (TM). This method integrates all reagent components onto a single, sophisticated card strip, enabling the completion of the assay in merely 20 minutes. Such efficiency enhances the potential for early screening of thrombosis within community and primary care medical institutions. The analytical performance results indicate that the limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) were determined to be 0.5, 0.8, and 1.2 TU mL<sup>-1</sup>, respectively. The repeatability and precision of the method were found to be significantly below 10%, with a linear range extending from 1.2 to 200 TU mL<sup>-1</sup>. Accuracy evaluations revealed relative biases of -3.35% and 4.79% for the two reference materials tested. Furthermore, clinical trials conducted across two clinical research centers involved a total of 236 clinical plasma samples. The results of the clinical analysis demonstrated excellent consistency with the reference reagent (Sysmex). The receiver operating characteristic (ROC) curve and significance analysis indicated that this method possesses commendable specificity and sensitivity. In summary, the single-integrated immunoassay method developed in this study represents a rapid, convenient, accurate, and sensitive detection approach. It is particularly well-suited for the early screening and diagnosis of thrombotic diseases in community and primary healthcare institutions.

Analytical MethodsVol. 17(40)
Jiangnan University (CN), Henan University (CN), Yancheng Central Blood Station (CN)
Openalex Percentile: Top 18%
Clinical Laboratory Practices and Quality Control
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.