First-in-Human Experience of Robotic-Assisted Transcatheter Aortic Valve Implantation with Femoral Artery Approach: A Case Report

Abstract Background Robotic-assisted transfemoral TAVI remains unreported. We present the first successful case using a novel robotic system. Case Summary A 70-year-old male with severe symptomatic aortic stenosis (mean gradient 52 mmHg, LVEF 48%) underwent robotic-assisted TAVI via femoral access. The procedure was remotely controlled from a radiation-shielded console using a Taurus Elite® 29mm valve. Key steps—wire navigation, balloon valvuloplasty, and valve deployment—were completed robotically in 11 minutes. Post-procedural TTE showed a peak gradient of 12 mmHg and LVEF improvement to 58% at 1 month, with no complications. Discussion This pioneering case confirms the feasibility of robotic TAVI, eliminating operator radiation exposure while maintaining procedural efficacy. The system’s integrated control may standardize complex valve deployments.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Case Reports
Published
2025-09-18
DOI
https://doi.org/10.1093/ehjcr/ytaf469
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First-in-Human Experience of Robotic-Assisted Transcatheter Aortic Valve Implantation with Femoral Artery Approach: A Case Report

Huaibin Huang, Yan Wang, Yi‐Wei Xu, Bin Wang et al.
European Heart Journal - Case Reports
Cardiac Valve Diseases and Treatments
article

First-in-Human Experience of Robotic-Assisted Transcatheter Aortic Valve Implantation with Femoral Artery Approach: A Case Report

Huaibin Huang, Yan Wang, Yi‐Wei Xu, Bin Wang, Lianglong Chen
article en

Abstract

Abstract Background Robotic-assisted transfemoral TAVI remains unreported. We present the first successful case using a novel robotic system. Case Summary A 70-year-old male with severe symptomatic aortic stenosis (mean gradient 52 mmHg, LVEF 48%) underwent robotic-assisted TAVI via femoral access. The procedure was remotely controlled from a radiation-shielded console using a Taurus Elite® 29mm valve. Key steps—wire navigation, balloon valvuloplasty, and valve deployment—were completed robotically in 11 minutes. Post-procedural TTE showed a peak gradient of 12 mmHg and LVEF improvement to 58% at 1 month, with no complications. Discussion This pioneering case confirms the feasibility of robotic TAVI, eliminating operator radiation exposure while maintaining procedural efficacy. The system’s integrated control may standardize complex valve deployments.

European Heart Journal - Case Reports
Zhongshan Hospital of Xiamen University (CN)
Openalex Percentile: Top 61%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

First-in-Human Experience of Robotic-Assisted Transcatheter Aortic Valve Implantation with Femoral Artery Approach: A Case Report — Huaibin Huang, Yan Wang, et al. · European Heart Journal - Case Reports (2025) | TGRS Research Map | TGRS