Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

Abstract In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mo>∼</mml:mo> <mml:mstyle scriptlevel="0"/> <mml:mstyle scriptlevel="0"/> <mml:mrow> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mn>10</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> <mml:mrow> <mml:mtext>c</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>m</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>3</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:mrow> </mml:math> . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

Authors

Institutions

Publication Details

Journal
Plasma Sources Science and Technology
Published
2025-09-19
DOI
https://doi.org/10.1088/1361-6595/ae0963
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

Ivan Romadanov, Sung Hyun Son, Nirbhav Singh Chopra, Yevgeny Raitses
Plasma Sources Science and Technology
Spectroscopy and Laser Applications
article

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

Ivan Romadanov, Sung Hyun Son, Nirbhav Singh Chopra, Yevgeny Raitses
article en

Abstract

Abstract In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mo>∼</mml:mo> <mml:mstyle scriptlevel="0"/> <mml:mstyle scriptlevel="0"/> <mml:mrow> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mn>10</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> <mml:mrow> <mml:mtext>c</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>m</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>3</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:mrow> </mml:math> . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

Plasma Sources Science and TechnologyVol. 34(10)
Princeton University (US), Princeton Plasma Physics Laboratory (US)
Openalex Percentile: Top 76%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.