Optimized shaped pulses for 2D-SIFTER

Abstract. Fast and accurate arbitrary waveform generators (AWG) for generating shaped pulses in EPR have been commercially available for over a decade now. However, while the use of chirp pulses as inversion pulses in pulsed electron double resonance (PELDOR) experiments has become common, their application for generating broadband phase-sensitive transverse magnetization is not widely adopted within the community. Here we give a detailed insight into optimization procedures and instrumental challenges when using chirped pulses for broadband Fourier transform (FT) detection of electron spin echo signals, particularly the two-dimensional frequency‑correlated single frequency technique for refocusing (SIFTER) experiment. To better understand the influence of chirped pulses on the generation of broadband transverse magnetization, we investigated the phase and amplitude of chirped echoes for different time-bandwidth products while varying the number of refocusing pulses, particularly under the influence of B1‑inhomogeneity. Following our optimization procedures, we were able to perform orientation selective SIFTER measurements using rigid nitroxide spin labels on an RNA duplex. Finally, we also demonstrate the first experiments with two novel SIFTER pulse sequences, which could be of interest for the detection of either shorter or longer distances.

Authors

Publication Details

Published
2025-09-19
DOI
https://doi.org/10.5194/mr-2025-11
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized shaped pulses for 2D-SIFTER

Burkhard Endeward, Paul Trenkler, Snorri Th. Sigurdsson, Thomas F. Prisner
1 citations
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Optimized shaped pulses for 2D-SIFTER

Burkhard Endeward, Paul Trenkler, Snorri Th. Sigurdsson, Thomas F. Prisner
article en
1 citations

Abstract

Abstract. Fast and accurate arbitrary waveform generators (AWG) for generating shaped pulses in EPR have been commercially available for over a decade now. However, while the use of chirp pulses as inversion pulses in pulsed electron double resonance (PELDOR) experiments has become common, their application for generating broadband phase-sensitive transverse magnetization is not widely adopted within the community. Here we give a detailed insight into optimization procedures and instrumental challenges when using chirped pulses for broadband Fourier transform (FT) detection of electron spin echo signals, particularly the two-dimensional frequency‑correlated single frequency technique for refocusing (SIFTER) experiment. To better understand the influence of chirped pulses on the generation of broadband transverse magnetization, we investigated the phase and amplitude of chirped echoes for different time-bandwidth products while varying the number of refocusing pulses, particularly under the influence of B1‑inhomogeneity. Following our optimization procedures, we were able to perform orientation selective SIFTER measurements using rigid nitroxide spin labels on an RNA duplex. Finally, we also demonstrate the first experiments with two novel SIFTER pulse sequences, which could be of interest for the detection of either shorter or longer distances.

Openalex Percentile: Top 12%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.