Influence of Gas Explosions in Utility Tunnels on the Structural Safety of Overhead Pipelines

For the possible damage to overhead pipelines caused by gas explosions in utility tunnels, an overall three-dimensional finite-element model of utility tunnel–soil–pipeline is established, the overpressure loads are applied to the inner wall of the gas chamber in the utility tunnel, the dynamic response laws of the utility tunnel and the pipeline are calculated and analyzed, and anti-explosion protection measures are proposed. The results show that the degree of damage to the pipe wall is determined by both the explosion-impacted area and the soil constraint. Under the same explosion-impacted area, the peak horizontal displacement of the monitoring point without soil constraint is 1.64 times that with soil constraint, and 1.29 times for the peak vertical displacement. The damage to the lower part of the pipeline is significantly greater than that to the upper part of the pipeline, and the damage to the pipeline decreases with an increase in the horizontal angle between the utility tunnel and the pipeline. The diameter deformation rates were 49% at α = 0° and 84% at α = 45°, with α = 90° showing the least damage. Therefore, it is suggested that the overhead pipeline is perpendicular to the utility tunnel. As the vertical distance between the utility tunnel and the pipeline increases, the diameter deformation rate and displacement of the pipeline both decrease, and when this distance is greater than 3 m, the influence on the pipeline significantly decreases. Therefore, it is recommended that the distance between the pipeline and the utility tunnel should be at least 3 m. In addition, the damage caused by gas explosions to the overhead pipeline can be reduced by reinforcing the gas chamber, using energy-absorbing materials around the utility tunnel, and setting up hollow piles between the utility tunnel and pipelines.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-09-19
DOI
https://doi.org/10.3390/buildings15183391
Citations
2
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
9.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Gas Explosions in Utility Tunnels on the Structural Safety of Overhead Pipelines

Jianmei Du, Julita Krassowska, Dai Wang, Xuan Chen et al.
2 citations
Buildings
Combustion and Detonation Processes
9.99
article

Influence of Gas Explosions in Utility Tunnels on the Structural Safety of Overhead Pipelines

Jianmei Du, Julita Krassowska, Dai Wang, Xuan Chen, Jian Dong
article en
2 citations

Abstract

For the possible damage to overhead pipelines caused by gas explosions in utility tunnels, an overall three-dimensional finite-element model of utility tunnel–soil–pipeline is established, the overpressure loads are applied to the inner wall of the gas chamber in the utility tunnel, the dynamic response laws of the utility tunnel and the pipeline are calculated and analyzed, and anti-explosion protection measures are proposed. The results show that the degree of damage to the pipe wall is determined by both the explosion-impacted area and the soil constraint. Under the same explosion-impacted area, the peak horizontal displacement of the monitoring point without soil constraint is 1.64 times that with soil constraint, and 1.29 times for the peak vertical displacement. The damage to the lower part of the pipeline is significantly greater than that to the upper part of the pipeline, and the damage to the pipeline decreases with an increase in the horizontal angle between the utility tunnel and the pipeline. The diameter deformation rates were 49% at α = 0° and 84% at α = 45°, with α = 90° showing the least damage. Therefore, it is suggested that the overhead pipeline is perpendicular to the utility tunnel. As the vertical distance between the utility tunnel and the pipeline increases, the diameter deformation rate and displacement of the pipeline both decrease, and when this distance is greater than 3 m, the influence on the pipeline significantly decreases. Therefore, it is recommended that the distance between the pipeline and the utility tunnel should be at least 3 m. In addition, the damage caused by gas explosions to the overhead pipeline can be reduced by reinforcing the gas chamber, using energy-absorbing materials around the utility tunnel, and setting up hollow piles between the utility tunnel and pipelines.

BuildingsVol. 15(18)
Bialystok University of Technology (PL), Tianjin Chengjian University (CN), North China Municipal Engineering Design & Research Institute (CN)
Tianjin Municipal Science and Technology Bureau
Openalex Percentile: Top 2%
Combustion and Detonation Processes
9.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.