Evaluating the Diagnostic Accuracy of an Artificial Intelligence Tool for Pulmonary Abnormalities in Chest Radiographs: A Retrospective Study

Introduction A retrospective, in-clinic study was conducted to validate the diagnostic performance of the Oxipit ChestEye™ AI tool in interpreting chest radiographs and to evaluate its impact on clinical outcomes and healthcare system efficiency. The performance of the AI model was compared with that of radiologists. Methods Chest radiographs from 1,470 patients, obtained from a public healthcare institution, were analyzed for nine pulmonary conditions: consolidation, heart enlargement, interstitial markers, linear atelectasis, no cardiopulmonary findings, nodule, pleural effusion, pneumothorax, and tuberculosis. Diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1 scores were calculated for Oxipit ChestEye™ and compared with radiologists' diagnoses, which served as the reference standard. Results The AI tool demonstrated accuracy ranging from 0.79 to 1.00 across the nine conditions evaluated. Sensitivity ranged from 0.25 to 1.00, and specificity ranged from 0.65 to 1.00. In differentiating between "Normal" and "Altered" categories, the AI model achieved an accuracy of 0.78. The F1 score for "Normal" was 0.86, whereas for "Altered," it was 0.52. Conclusions Oxipit ChestEye™ demonstrated high accuracy and efficiency in detecting and triaging pulmonary abnormalities in chest radiographs. While it is a useful tool to supplement the work of the radiologists, helping to reduce diagnostic time and improve patient care, it should not replace human radiologists.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-09-19
DOI
https://doi.org/10.7759/cureus.92690
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Diagnostic Accuracy of an Artificial Intelligence Tool for Pulmonary Abnormalities in Chest Radiographs: A Retrospective Study

Eric Pinheiro de Andrade, Marcelo Itiro Takano, Mauro Gobira, M Amaral et al.
Cureus
Advanced X-ray and CT Imaging
article

Evaluating the Diagnostic Accuracy of an Artificial Intelligence Tool for Pulmonary Abnormalities in Chest Radiographs: A Retrospective Study

Eric Pinheiro de Andrade, Marcelo Itiro Takano, Mauro Gobira, M Amaral, Osvaldo Landi Júnior, Gladstone Mattar
article en

Abstract

Introduction A retrospective, in-clinic study was conducted to validate the diagnostic performance of the Oxipit ChestEye™ AI tool in interpreting chest radiographs and to evaluate its impact on clinical outcomes and healthcare system efficiency. The performance of the AI model was compared with that of radiologists. Methods Chest radiographs from 1,470 patients, obtained from a public healthcare institution, were analyzed for nine pulmonary conditions: consolidation, heart enlargement, interstitial markers, linear atelectasis, no cardiopulmonary findings, nodule, pleural effusion, pneumothorax, and tuberculosis. Diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1 scores were calculated for Oxipit ChestEye™ and compared with radiologists' diagnoses, which served as the reference standard. Results The AI tool demonstrated accuracy ranging from 0.79 to 1.00 across the nine conditions evaluated. Sensitivity ranged from 0.25 to 1.00, and specificity ranged from 0.65 to 1.00. In differentiating between "Normal" and "Altered" categories, the AI model achieved an accuracy of 0.78. The F1 score for "Normal" was 0.86, whereas for "Altered," it was 0.52. Conclusions Oxipit ChestEye™ demonstrated high accuracy and efficiency in detecting and triaging pulmonary abnormalities in chest radiographs. While it is a useful tool to supplement the work of the radiologists, helping to reduce diagnostic time and improve patient care, it should not replace human radiologists.

CureusVol. 17(9)
Centrus Diagnósticos por Imagem (BR), Instituto da Visão (BR), Hospital do Servidor Público Estadual (BR), Universidade Federal de São Paulo (BR)
Openalex Percentile: Top 75%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the Diagnostic Accuracy of an Artificial Intelligence Tool for Pulmonary Abnormalities in Chest Radiographs: A Retrospective Study — Eric Pinheiro de Andrade, Marcelo Itiro Takano, et al. · Cureus (2025) | TGRS Research Map | TGRS