Monte Carlo Calculations of Correction Coefficients for a Proton Calorimeter

Abstract. The presence of vacuum gaps in calorimeters designed to measure doses of ionizing adiation leads to a change in particle flux, which in turn leads to a change in the value of the absorbed dose at the measuring point from the value that would be in a homogeneous medium. The results of Monte Carlo calculations of correction coefficients that take into account the distortion of the fluence of protons in a medical beam with a proton energy from 50 to 250 MeV for a proton calorimeter developed by VNIIFTRI are presented. The results obtained were used to determine the absorbed dose of proton radiation with a calorimeter included in the State Primary Standard GET 38-2024.

Authors

Institutions

Publication Details

Journal
ANRI
Published
2025-09-16
DOI
https://doi.org/10.37414/2075-1338-2025-122-3-29-37
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo Calculations of Correction Coefficients for a Proton Calorimeter

V. F. Batyaev, A. V. Berlyand, V. A. Berlyand, Yu. E. Titarenko et al.
ANRI
Radiation Detection and Scintillator Technologies
article

Monte Carlo Calculations of Correction Coefficients for a Proton Calorimeter

V. F. Batyaev, A. V. Berlyand, V. A. Berlyand, Yu. E. Titarenko, K. V. Pavlov
article en

Abstract

Abstract. The presence of vacuum gaps in calorimeters designed to measure doses of ionizing adiation leads to a change in particle flux, which in turn leads to a change in the value of the absorbed dose at the measuring point from the value that would be in a homogeneous medium. The results of Monte Carlo calculations of correction coefficients that take into account the distortion of the fluence of protons in a medical beam with a proton energy from 50 to 250 MeV for a proton calorimeter developed by VNIIFTRI are presented. The results obtained were used to determine the absorbed dose of proton radiation with a calorimeter included in the State Primary Standard GET 38-2024.

ANRIVol. 0(3)
Kurchatov Institute (RU), Vladimir State University (RU)
Openalex Percentile: Top 67%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Monte Carlo Calculations of Correction Coefficients for a Proton Calorimeter — V. F. Batyaev, A. V. Berlyand, et al. · ANRI (2025) | TGRS Research Map | TGRS