Determination of the Optimal Time for the Use of Thermoluminescent Dosimeters when Conducting Individual Dosimetric Monitoring Using the Harshaw Thermoluminescent Dosimetric Automated System

Abstract. An experiment of measuring of the dose accumulation rate of 120 Harshaw slides type 0110 over three months was conducted. It was revealed that the results of measuring the accumulated dose after annealing the dosimeter are not equal to zero, but are about 0,1 mSv. Subsequent daily measurements of other dosimeters showed that the dose rate was about 0,00344 ± 0,00025 mSv§day, which does not correspond to the dosimeter-radiometer MKS‑AT1117M readings of 0,0046 ± 0,0009 mSv§day. It has been suggested that it is necessary to take into account the identified effect when determining the individual dose equivalent of external irradiation to the lower abdomen for women of reproductive age or to use a fundamentally new method for determining this value.

Authors

Institutions

Publication Details

Journal
ANRI
Published
2025-09-16
DOI
https://doi.org/10.37414/2075-1338-2025-122-3-46-56
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Optimal Time for the Use of Thermoluminescent Dosimeters when Conducting Individual Dosimetric Monitoring Using the Harshaw Thermoluminescent Dosimetric Automated System

А. И. Коваленко, E. V. Yurchenko, М. М. Балачков
ANRI
Radiation Detection and Scintillator Technologies
article

Determination of the Optimal Time for the Use of Thermoluminescent Dosimeters when Conducting Individual Dosimetric Monitoring Using the Harshaw Thermoluminescent Dosimetric Automated System

А. И. Коваленко, E. V. Yurchenko, М. М. Балачков
article en

Abstract

Abstract. An experiment of measuring of the dose accumulation rate of 120 Harshaw slides type 0110 over three months was conducted. It was revealed that the results of measuring the accumulated dose after annealing the dosimeter are not equal to zero, but are about 0,1 mSv. Subsequent daily measurements of other dosimeters showed that the dose rate was about 0,00344 ± 0,00025 mSv§day, which does not correspond to the dosimeter-radiometer MKS‑AT1117M readings of 0,0046 ± 0,0009 mSv§day. It has been suggested that it is necessary to take into account the identified effect when determining the individual dose equivalent of external irradiation to the lower abdomen for women of reproductive age or to use a fundamentally new method for determining this value.

ANRIVol. 0(3)
National Research Tomsk State University (RU), Tomsk Polytechnic University (RU), Concern Energomera (Russia) (RU)
Openalex Percentile: Top 67%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.