The Susceptibility of Airborne SARS-CoV-2 to Far-UVC Irradiation

Far-ultraviolet-C (far-UVC) irradiation has emerged as a breakthrough disinfection technology for the treatment of indoor air. Far-UVC wavelengths (222 nm) from filtered krypton-chloride excimer lamps are effective at inactivating airborne viruses and are safe for human exposure, thus enabling the continuous treatment of bulk air in occupied settings. This study quantifies the susceptibility of airborne SARS-CoV-2, aerosolized in human saliva, to far-UVC radiation. We measured fluence rate-based <i>Z</i>-value susceptibility constants (±standard error) of 4.4 ± 0.6 and 6.8 ± 0.7 cm<sup>2</sup> mJ<sup>-1</sup> for airborne SARS-CoV-2 under 40% and 65% relative humidity (RH) levels, respectively. At modeled far-UVC irradiation levels corresponding to 25% of the maximum safe human exposure limit, the resulting far-UVC equivalent air changes per hour (eACH) exceeded 62 h<sup>-1</sup> at 65% RH and were significantly greater than the corresponding airborne SARS-CoV-2 natural decay rate (±standard error) of 5.4 ± 1.1 h<sup>-1</sup>, measured in the absence of far-UVC. These results define first-order loss rates for airborne SARS-CoV-2 under far-UVC exposure and support quantitative risk assessments and rational disinfection system implementation.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2025-09-19
DOI
https://doi.org/10.1021/acs.est.5c09275
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Susceptibility of Airborne SARS-CoV-2 to Far-UVC Irradiation

Darryl M. Angel, Keyla Santos Guedes de Sá, Jordan Peccia, Irvan Luhung
1 citations
Environmental Science & Technology
Infection Control and Ventilation
1.52
article

The Susceptibility of Airborne SARS-CoV-2 to Far-UVC Irradiation

Darryl M. Angel, Keyla Santos Guedes de Sá, Jordan Peccia, Irvan Luhung
article en
1 citations

Abstract

Far-ultraviolet-C (far-UVC) irradiation has emerged as a breakthrough disinfection technology for the treatment of indoor air. Far-UVC wavelengths (222 nm) from filtered krypton-chloride excimer lamps are effective at inactivating airborne viruses and are safe for human exposure, thus enabling the continuous treatment of bulk air in occupied settings. This study quantifies the susceptibility of airborne SARS-CoV-2, aerosolized in human saliva, to far-UVC radiation. We measured fluence rate-based <i>Z</i>-value susceptibility constants (±standard error) of 4.4 ± 0.6 and 6.8 ± 0.7 cm<sup>2</sup> mJ<sup>-1</sup> for airborne SARS-CoV-2 under 40% and 65% relative humidity (RH) levels, respectively. At modeled far-UVC irradiation levels corresponding to 25% of the maximum safe human exposure limit, the resulting far-UVC equivalent air changes per hour (eACH) exceeded 62 h<sup>-1</sup> at 65% RH and were significantly greater than the corresponding airborne SARS-CoV-2 natural decay rate (±standard error) of 5.4 ± 1.1 h<sup>-1</sup>, measured in the absence of far-UVC. These results define first-order loss rates for airborne SARS-CoV-2 under far-UVC exposure and support quantitative risk assessments and rational disinfection system implementation.

Environmental Science & TechnologyVol. 59(38)
Yale University (US)
Openalex Percentile: Top 14%
Infection Control and Ventilation
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.