RMO Supplementary Comparison EURAMET.EM-S46 High voltage comparison of DC ratio

Main text Different methods were used for the 20000:1 high DC voltage ratio (scale factor) calibration up to 200 kV by the participating laboratories. The traceability was based either on calibration of divider resistance values at 1 kV, or on voltage-ratio based devices used at 1 kV, 10 kV or 50 kV. Voltage-ratio based devices were traceable either to a Josephson voltage standard or to a self-calibrating ratio standard. After removal of one outlier, the expanded uncertainty (k=2) of the reference value at 1 kV was 1.7·10 -6 , increasing up to 3.2·10 -6 on higher voltages. Comparison on voltages above 1 kV was based on the low voltage calibration, and on the previously determined voltage coefficient of the divider design. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/01006
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RMO Supplementary Comparison EURAMET.EM-S46 High voltage comparison of DC ratio

M. Hammarquist, Ahmet Merev, Alf-Peter Elg, Stephan Passon et al.
Metrologia
Magnetic Properties and Applications
article

RMO Supplementary Comparison EURAMET.EM-S46 High voltage comparison of DC ratio

M. Hammarquist, Ahmet Merev, Alf-Peter Elg, Stephan Passon, Serkan Dedeoglu, Jussi Havunen, Ernest Houtzager, Johann Meisner, Jari Hällström, G Rietveld
article en

Abstract

Main text Different methods were used for the 20000:1 high DC voltage ratio (scale factor) calibration up to 200 kV by the participating laboratories. The traceability was based either on calibration of divider resistance values at 1 kV, or on voltage-ratio based devices used at 1 kV, 10 kV or 50 kV. Voltage-ratio based devices were traceable either to a Josephson voltage standard or to a self-calibrating ratio standard. After removal of one outlier, the expanded uncertainty (k=2) of the reference value at 1 kV was 1.7·10 -6 , increasing up to 3.2·10 -6 on higher voltages. Comparison on voltages above 1 kV was based on the low voltage calibration, and on the previously determined voltage coefficient of the divider design. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
Physikalisch-Technische Bundesanstalt (DE), Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (TR), RISE Research Institutes of Sweden (SE), Thales (Netherlands) (NL), Tübitak National Metrology Institute (TR), VSL National Metrology Institute (NL), VTT Technical Research Centre of Finland (FI)
Openalex Percentile: Top 83%
Magnetic Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.