NewATHENA x-ray optic: current status of post-thermal test performance at PANTER

With the transformation of ATHENA into the NewATHENA mission, cutting-edge Silicon Pore Optics (SPOs) have evolved to meet the stringent requirements of future space-based observatories. During the redefinition phase, SPO technology was significantly improved, leading to the creation of the first mirror modules that fully meet the NewATHENA design, with precise dimensions, rib spacing, and coatings. In 2024, these NewATHENA SPOs underwent detailed performance characterization, including measurements of the half-energy widths of the on- and off-axis point spread function, at the PANTER x-ray test facility of the Max Planck Institute for Extraterrestrial Physics. Additionally, effective area assessments were conducted across the energy range relevant to NewATHENA. This work presents a comparison of results obtained before and after the thermal test from campaigns conducted in December 2023 and November 2024, focusing on SPO MM-0058, the first representative NewATHENA row-08 mirror module.

Authors

Institutions

Publication Details

Published
2025-09-18
DOI
https://doi.org/10.1117/12.3064381
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NewATHENA x-ray optic: current status of post-thermal test performance at PANTER

Giuseppe Vacanti, Gisela Hartner, Marcos Bavdaz, Surangkhana Rukdee et al.
Particle Detector Development and Performance
article

NewATHENA x-ray optic: current status of post-thermal test performance at PANTER

Giuseppe Vacanti, Gisela Hartner, Marcos Bavdaz, Surangkhana Rukdee, Thomas Schmidt, Boris Landgraf, Thomas Müller, Nicolas M. Barrière, V. Burwitz, Maximilien J. Collon, Andreas Langmeier
article en

Abstract

With the transformation of ATHENA into the NewATHENA mission, cutting-edge Silicon Pore Optics (SPOs) have evolved to meet the stringent requirements of future space-based observatories. During the redefinition phase, SPO technology was significantly improved, leading to the creation of the first mirror modules that fully meet the NewATHENA design, with precise dimensions, rib spacing, and coatings. In 2024, these NewATHENA SPOs underwent detailed performance characterization, including measurements of the half-energy widths of the on- and off-axis point spread function, at the PANTER x-ray test facility of the Max Planck Institute for Extraterrestrial Physics. Additionally, effective area assessments were conducted across the energy range relevant to NewATHENA. This work presents a comparison of results obtained before and after the thermal test from campaigns conducted in December 2023 and November 2024, focusing on SPO MM-0058, the first representative NewATHENA row-08 mirror module.

Max Planck Institute for Extraterrestrial Physics (DE), Cosine (Netherlands) (NL)
Openalex Percentile: Top 89%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.