A curve-based radiometric calibration method for wavelength of interest hyperspectral imaging: a case study of QMX-1/CCTF-HI

Wavelength of interest (WOI) hyperspectral imaging technology offers significant advantages in optimizing mission-specific goals and improving cost-effectiveness in hyperspectral Earth observation. However, conducting per-band measurements for periodic on-orbit radiometric calibration across thousands of wavebands over the entire spectral range presents a considerable challenge, especially given the limited resources available on satellite platforms and at ground stations. To overcome this, we propose the Curve-based Hyperspectral Imaging Radiometric Calibration (CHIRON) method. This method generates radiometric calibration coefficient (RCC) curves across the imaging spectrum by leveraging the wavelength-dependent optical properties of the system. Integrated within the vicarious calibration workflow of the Radiometric Calibration Network (RadCalNet), CHIRON is applied to the Compact Continuous Tunable LVF-based Hyperspectral Imager (CCTF-HI) onboard the QMX-1 microsatellite. The CCTF-HI is a hyperspectral imager based on a linear variable filter (LVF), operating across the 400–1000 nm spectral range with a 0.287 nm interval, enabling WOI hyperspectral imaging. We employ cubic polynomial regression models to reconstruct the RCC distribution, achieving optimal fits with all models showing [Formula: see text]. We validated the radiometric performance of the CHIRON method using three different WOI imaging modes, each capturing a distinct subset of selectable wavebands from QMX–1/CCTF–HI. Reflectance measurements from these modes were compared with RadCalNet products, ground-based spectroscopy, and near-coincident imagery from an independent reference sensor. All absolute errors remained within 0.05 reflectance units, demonstrating that the RCC curve preserves radiometric fidelity even without band–specific calibration. By eliminating exhaustive per–band radiometric characterization, CHIRON reduces calibration workload and computational demand, enabling precise yet resource–efficient WOI hyperspectral imaging – particularly valuable for microsatellite with constrained onboard processing.

Authors

Institutions

Publication Details

Journal
Geo-spatial Information Science
Published
2025-09-18
DOI
https://doi.org/10.1080/10095020.2025.2547951
Citations
1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A curve-based radiometric calibration method for wavelength of interest hyperspectral imaging: a case study of QMX-1/CCTF-HI

Zhaocong Wu, Siqing Zhang, Zhengcan Li, Shaoju Wang et al.
1 citations
Geo-spatial Information Science
Calibration and Measurement Techniques
4.99
article

A curve-based radiometric calibration method for wavelength of interest hyperspectral imaging: a case study of QMX-1/CCTF-HI

Zhaocong Wu, Siqing Zhang, Zhengcan Li, Shaoju Wang, Xuemin Zhang, Liangliang Zheng, Nan Xie, Keyi Rao, Weixing Xu, Run Fang, Z.-B. Dai
article en
1 citations

Abstract

Wavelength of interest (WOI) hyperspectral imaging technology offers significant advantages in optimizing mission-specific goals and improving cost-effectiveness in hyperspectral Earth observation. However, conducting per-band measurements for periodic on-orbit radiometric calibration across thousands of wavebands over the entire spectral range presents a considerable challenge, especially given the limited resources available on satellite platforms and at ground stations. To overcome this, we propose the Curve-based Hyperspectral Imaging Radiometric Calibration (CHIRON) method. This method generates radiometric calibration coefficient (RCC) curves across the imaging spectrum by leveraging the wavelength-dependent optical properties of the system. Integrated within the vicarious calibration workflow of the Radiometric Calibration Network (RadCalNet), CHIRON is applied to the Compact Continuous Tunable LVF-based Hyperspectral Imager (CCTF-HI) onboard the QMX-1 microsatellite. The CCTF-HI is a hyperspectral imager based on a linear variable filter (LVF), operating across the 400–1000 nm spectral range with a 0.287 nm interval, enabling WOI hyperspectral imaging. We employ cubic polynomial regression models to reconstruct the RCC distribution, achieving optimal fits with all models showing [Formula: see text]. We validated the radiometric performance of the CHIRON method using three different WOI imaging modes, each capturing a distinct subset of selectable wavebands from QMX–1/CCTF–HI. Reflectance measurements from these modes were compared with RadCalNet products, ground-based spectroscopy, and near-coincident imagery from an independent reference sensor. All absolute errors remained within 0.05 reflectance units, demonstrating that the RCC curve preserves radiometric fidelity even without band–specific calibration. By eliminating exhaustive per–band radiometric characterization, CHIRON reduces calibration workload and computational demand, enabling precise yet resource–efficient WOI hyperspectral imaging – particularly valuable for microsatellite with constrained onboard processing.

Geo-spatial Information Science
Chinese Academy of Sciences (CN), Wuhan University (CN), Changchun Institute of Optics, Fine Mechanics and Physics (CN), Henan Academy of Sciences (CN), Aerospace Information Research Institute (CN)
Openalex Percentile: Top 5%
Calibration and Measurement Techniques
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.