F-UTransBPNet A Transformer-Enhanced U-Net for Cuffless Blood Pressure Estimation Across Activity Scenarios

Continuous blood pressure (BP) monitoring is essential for early detection and management of hypertension, a major risk factor for cardiovascular disease and death. Traditional cuff-based devices are not suitable for continuous or ambulatory monitoring because they can cause discomfort and only provide intermittent measurements. This has led to the development of cuffless BP estimation methods that utilize physiological signals like electrocardiography (ECG) and photoplethysmography (PPG). Existing deep learning techniques, such as convolutional neural networks (CNNs) and hybrid CNN–LSTM models, have shown promising results in controlled settings; however, they often face challenges in maintaining performance under changing physiological conditions. To address this issue, we introduce F-UTransBPNet, a hybrid U-Net–Transformer architecture that combines local feature extraction with long-range temporal modeling, further optimized through selective fine-tuning. The model was trained and tested on three complementary datasets: MIMIC (ICU patients), Dataset_Drink (water intake), and Dataset_Exercise (bicycle ergometry), covering both static and activity-based scenarios. Results show that F-UTransBPNet achieves mean absolute differences of 4.4 mmHg (SBP) and 2.2 mmHg (DBP) when compared to invasive references, meeting AAMI standards, and maintains strong correlations in activity datasets (PCC up to 0.82 for SBP). Minimal fine-tuning with just 10–20% of scenario-specific data restores performance across different domains, demonstrating the feasibility of calibration-light operation. These findings indicate that F-UTransBPNet offers an effective balance of accuracy, adaptability, and computational efficiency, supporting its potential as a reliable tool for cuffless BP monitoring in both inpatient and wearable healthcare settings.

Authors

Publication Details

Journal
Journal of Machine Intelligence in Healthcare
Published
2025-09-19
DOI
https://doi.org/10.70062/jmih.v1i2.169
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

F-UTransBPNet A Transformer-Enhanced U-Net for Cuffless Blood Pressure Estimation Across Activity Scenarios

Muhammad Lutfi, Emmanouela Vogiatzi
Journal of Machine Intelligence in Healthcare
Non-Invasive Vital Sign Monitoring
article

F-UTransBPNet A Transformer-Enhanced U-Net for Cuffless Blood Pressure Estimation Across Activity Scenarios

Muhammad Lutfi, Emmanouela Vogiatzi
article en

Abstract

Continuous blood pressure (BP) monitoring is essential for early detection and management of hypertension, a major risk factor for cardiovascular disease and death. Traditional cuff-based devices are not suitable for continuous or ambulatory monitoring because they can cause discomfort and only provide intermittent measurements. This has led to the development of cuffless BP estimation methods that utilize physiological signals like electrocardiography (ECG) and photoplethysmography (PPG). Existing deep learning techniques, such as convolutional neural networks (CNNs) and hybrid CNN–LSTM models, have shown promising results in controlled settings; however, they often face challenges in maintaining performance under changing physiological conditions. To address this issue, we introduce F-UTransBPNet, a hybrid U-Net–Transformer architecture that combines local feature extraction with long-range temporal modeling, further optimized through selective fine-tuning. The model was trained and tested on three complementary datasets: MIMIC (ICU patients), Dataset_Drink (water intake), and Dataset_Exercise (bicycle ergometry), covering both static and activity-based scenarios. Results show that F-UTransBPNet achieves mean absolute differences of 4.4 mmHg (SBP) and 2.2 mmHg (DBP) when compared to invasive references, meeting AAMI standards, and maintains strong correlations in activity datasets (PCC up to 0.82 for SBP). Minimal fine-tuning with just 10–20% of scenario-specific data restores performance across different domains, demonstrating the feasibility of calibration-light operation. These findings indicate that F-UTransBPNet offers an effective balance of accuracy, adaptability, and computational efficiency, supporting its potential as a reliable tool for cuffless BP monitoring in both inpatient and wearable healthcare settings.

Journal of Machine Intelligence in HealthcareVol. 1(2)
Openalex Percentile: Top 76%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.