Fiber Bragg Grating Embedded 3D-Printed Insole with Commercial and Portable Reader for Stance Phase Determination

This paper presents development and application of a Fiber Bragg Grating (FBG) array embedded in a 3D-printed insole for ground reaction force (GRF) estimation. In this case, a 3D-printed insole is fabricated from a scanned commercial insole in which a 5-FBGs array is integrated. The FBGs are characterized as a function of the applied transverse force, where a mean sensitivity of 0.11 ± 0.10 pm/N was obtained considering all FBGs. A portable FBG signal acquisition system was connected to the FBG array embedded in the insole and tested for the GRF analysis in a healthy volunteer. The gait tests results indicate stance and swing phases of 41.0 ± 6.5% and 59 ± 6.5%, respectively, which are within reference values of the literature. Furthermore, a 0.904 R<sup>2</sup> was found in the correlation analysis of the measured GRF response and the conventional M-shaped curve for the GRF in which all subdivisions of the stance phase were detected.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-09-19
DOI
https://doi.org/10.3390/bios15090623
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fiber Bragg Grating Embedded 3D-Printed Insole with Commercial and Portable Reader for Stance Phase Determination

Radek Martínek, Jan Nedoma, Arnaldo Leal‐Junior, Mariana Silveira
Biosensors
Non-Invasive Vital Sign Monitoring
article

Fiber Bragg Grating Embedded 3D-Printed Insole with Commercial and Portable Reader for Stance Phase Determination

Radek Martínek, Jan Nedoma, Arnaldo Leal‐Junior, Mariana Silveira
article en

Abstract

This paper presents development and application of a Fiber Bragg Grating (FBG) array embedded in a 3D-printed insole for ground reaction force (GRF) estimation. In this case, a 3D-printed insole is fabricated from a scanned commercial insole in which a 5-FBGs array is integrated. The FBGs are characterized as a function of the applied transverse force, where a mean sensitivity of 0.11 ± 0.10 pm/N was obtained considering all FBGs. A portable FBG signal acquisition system was connected to the FBG array embedded in the insole and tested for the GRF analysis in a healthy volunteer. The gait tests results indicate stance and swing phases of 41.0 ± 6.5% and 59 ± 6.5%, respectively, which are within reference values of the literature. Furthermore, a 0.904 R<sup>2</sup> was found in the correlation analysis of the measured GRF response and the conventional M-shaped curve for the GRF in which all subdivisions of the stance phase were detected.

BiosensorsVol. 15(9)
VSB - Technical University of Ostrava (CZ), Universidade Federal do Espírito Santo (BR)
Openalex Percentile: Top 76%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.